By juma , 27 February, 2023 Forums General discussion Hello Mikko, I am trying to read the SL7000 billing profile with: profileGenerics = GXDLMSProfileGeneric("0.1.98.1.0.105") captureObjects = reader.read(profileGenerics, 3) datos = reader.readRowsByEntry(profileGenerics,1,1) and i can´t find the Aggregate Active Import Max 1 Rate 1. (1.1.1.6.1.255) in datos, could you help me? what am i doing wrong? Hi, If Aggregate Active… Hi, If Aggregate Active Import Max 1 Rate 1 is not in the capture objects, then it's not saved for the historical values. Check if it's saved for some other profile generic. BR, Mikko
Hi, If Aggregate Active… Hi, If Aggregate Active Import Max 1 Rate 1 is not in the capture objects, then it's not saved for the historical values. Check if it's saved for some other profile generic. BR, Mikko
Hi, If Aggregate Active…
Hi,
If Aggregate Active Import Max 1 Rate 1 is not in the capture objects, then it's not saved for the historical values. Check if it's saved for some other profile generic.
BR,
Mikko