CTT tool version
ctt 3.1 standard 64-bits release 107
Failed case :
T_HDLC_INFO_N3
Wrong N(S) sequence number FAILED(Response not RR)
Send AARQ with wrong sequence number.
This test is used to check that meter can handle if AARQ is sent with wrong sequence number.
DLMS CTT 3.1: T_HDLC_INFO_N3
We improved something else some time ago and didn't realize that this improvement will break HDLC tests. There is a new version available where this is fixed. http://www.gurux.fi/node/17965
Hi,
Hi,
We improved something else some time ago and didn't realize that this improvement will break HDLC tests. There is a new version available where this is fixed.
http://www.gurux.fi/node/17965
BR,
Mikko