Starting with DLMS and a ZIV meter

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Pelmar , 15 December, 2015
Forums
DLMSDirector

Good day,

I´m starting with DLMSDirector and the smart meter ZIV 5CTM. I have been changing the configuration serveral times, but i could´t stablish connection with the meter. Reading other topics I realice that the smart meter doesn´t have the dlms identification in the meter. ¿Does this mean that is not compilant with dlms standart? I ask the manufacturer, and they said that it should work.

¿Any ideas?

Log created 17:44:06
17:44:09 Initializing serial connection.
17:44:10 Send SNRM request.
7E A0 07 03 03 93 8C 11 7E
17:44:15 Failed to receive reply from the device in given time.
System.Exception: Failed to receive reply from the device in given time.
en GXDLMSDirector.GXDLMSDevice.InitializeConnection() en C:\Projects\GXDLMSDirector\Development\GXDLMSDevice.cs:línea 345
en GXDLMSDirector.MainForm.Connect(Control sender, Object[] parameters) en C:\Projects\GXDLMSDirector\Development\MainForm.cs:línea 939

Thanks for your time

Profile picture for user Administrator

Administrator

10 years 5 months ago

ZIV meters

Hi,

We are Readingin some ZIV meters, but we are using TCP/IP connection and are are using serial port. Am I right? Your settings are wrong. Try to change client id to 10.

Pelmar

10 years 4 months ago

Ziv

Hi ,

We are trying to read the meter trought a IEC 62056-21 optical probe. We change the configuration as suggested but we still receive the same answer....

Thanks

Profile picture for user Kurumi

Kurumi

10 years 4 months ago

ZIV meters

Hi,

As I told we are reading Ziv meters throught TCP/IP, but try to
change starting protocol to IEC from DLMS.

Serial port settings are always little problematic,
but after they are correct you should be able to read your meter.

BR,

Mikko

Pelmar

10 years 4 months ago

Ziv meters

Hello Mikko,

Thanks for your quick answer.
I contacted with the manufacturer and in theory, the meter uses DLMS over HDLC and the port configuration is 9600-8-N-1. Gurux supports this specification ,right?. When you say that you are connecting througt TCP/IP you mean that you are using a RS232/Ethernet gatway? I will test it using one i have at home.

I have been playing changing the parameters as you recomenden but nothing, and I still don´t receive the firt sign of life.

This device as I said previosly don´t have the DLMS label instead has the PRIME (DLMS over PLC).

May be this unit have a different configuration?

Thanks a lot

Profile picture for user Kurumi

Kurumi

10 years 4 months ago

Ziv meters

Hi,

Yes, we are supporting that. We are reading other meter from ZIV where is TCP/IP interface.

Try first with these settings:
Client address: 1
Server address: 1

If that fails, can you ask what client and server address manufacturer is using for that meter.
We can solve them, but it's faster to ask from the manufacturer.
BR,

Mikko

marcogohi

8 years 4 months ago

We have the same problem as

We have the same problem as Pelmar with ZIV meters through serial coms.

Any update?

Profile picture for user Kurumi

Kurumi

8 years 4 months ago

Ziv meters

Hi,

What serial port settings you are using? Are you using optical head or serial port connection?

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin