Hi,

Client has requested to configure the Push Schedule.

Could you please suggest which value I have to configure and which object I should use to configure the Push schedule.

Regards,

Profile picture for user Kurumi

Kurumi

9 years 2 months ago

Push Schedule Configuration

Hi,

Basically you can send any data you like. Because several Club members have ask this lately, we created own topic for this.
http://www.gurux.fi/Gurux.DLMS.Push

BR,
Mikko

Goutam

9 years 1 month ago

Push Schedule Configuration

Hi,

I have tried with following code to configure push schedule in HPL meter.

GXDLMSPushSetup pushSchedule = new GXDLMSPushSetup();
pushSchedule.Destination = "xx.xxx.xxx.x:port";
pushSchedule.Service = Gurux.DLMS.Objects.Enums.ServiceType.Tcp;
pushSchedule.RandomisationStartInterval = 300;
pushSchedule.NumberOfRetries = 5;
pushSchedule.RepetitionDelay = 10;

List<KeyValuePair<GXDLMSObject, GXDLMSCaptureObject>> pushobjects = new List<KeyValuePair<GXDLMSObject, GXDLMSCaptureObject>>();
pushobjects.Add(new KeyValuePair<GXDLMSObject, GXDLMSCaptureObject>(pushSchedule, new GXDLMSCaptureObject(2, 0)));
GXDLMSData ldn = new GXDLMSData("0.0.42.0.0.255");
pushobjects.Add(new KeyValuePair<GXDLMSObject, GXDLMSCaptureObject>(ldn, new GXDLMSCaptureObject(2, 0)));
pushSchedule.PushObjectList = pushobjects;
grxComm.Write(pushSchedule, 7);

Error: Access Error : Device reports a hardware fault.

Could you please suggest me where I am wrong.

Regards,

Profile picture for user Kurumi

Kurumi

9 years 1 month ago

Push Schedule Configuration

Hi,

Can you see Push Setup object in GXDLMSDirector?

BR,

Mikko

Goutam

9 years 1 month ago

Push Schedule Configuration

Hi,

HPL meter is dynamic IP meter.

Regards,

Profile picture for user Kurumi

Kurumi

8 years 11 months ago

Push Schedule Configuration

Hi,

Can you read HPL meter using optical head?

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Landis E650 meter reading over DLMS
  • class_id = 40, version = 2, pushsetup Unparsed data frame
  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined
More

Who's new

  • Sayang
  • q80435762@gmail.com
  • ONCAK
  • Berhasil
  • ratirvivege1979
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin