Hi,

Client has requested to configure the Push Schedule.

Could you please suggest which value I have to configure and which object I should use to configure the Push schedule.

Regards,

Profile picture for user Kurumi

Kurumi

8 years 11 months ago

Push Schedule Configuration

Hi,

Basically you can send any data you like. Because several Club members have ask this lately, we created own topic for this.
http://www.gurux.fi/Gurux.DLMS.Push

BR,
Mikko

Goutam

8 years 9 months ago

Push Schedule Configuration

Hi,

I have tried with following code to configure push schedule in HPL meter.

GXDLMSPushSetup pushSchedule = new GXDLMSPushSetup();
pushSchedule.Destination = "xx.xxx.xxx.x:port";
pushSchedule.Service = Gurux.DLMS.Objects.Enums.ServiceType.Tcp;
pushSchedule.RandomisationStartInterval = 300;
pushSchedule.NumberOfRetries = 5;
pushSchedule.RepetitionDelay = 10;

List<KeyValuePair<GXDLMSObject, GXDLMSCaptureObject>> pushobjects = new List<KeyValuePair<GXDLMSObject, GXDLMSCaptureObject>>();
pushobjects.Add(new KeyValuePair<GXDLMSObject, GXDLMSCaptureObject>(pushSchedule, new GXDLMSCaptureObject(2, 0)));
GXDLMSData ldn = new GXDLMSData("0.0.42.0.0.255");
pushobjects.Add(new KeyValuePair<GXDLMSObject, GXDLMSCaptureObject>(ldn, new GXDLMSCaptureObject(2, 0)));
pushSchedule.PushObjectList = pushobjects;
grxComm.Write(pushSchedule, 7);

Error: Access Error : Device reports a hardware fault.

Could you please suggest me where I am wrong.

Regards,

Profile picture for user Kurumi

Kurumi

8 years 9 months ago

Push Schedule Configuration

Hi,

Can you see Push Setup object in GXDLMSDirector?

BR,

Mikko

Goutam

8 years 9 months ago

Push Schedule Configuration

Hi,

HPL meter is dynamic IP meter.

Regards,

Profile picture for user Kurumi

Kurumi

8 years 7 months ago

Push Schedule Configuration

Hi,

Can you read HPL meter using optical head?

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • CTKNhZElptjSlOrpkXl
  • YCbccqfLGRMnlCWoJhXP
  • Malcolmactig
  • mhliang
  • Kevinmug
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin