GXDLMSClient Server address size 4 wrong order

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By horcsa , 8 August, 2017
Forums
Gurux.DLMS

Hi,

I've an existing Actaris Electricity meter system, that was installed by another firm so I've got only few information. I'm trying to listen into the communication throught the serial port and I see that the SNRM request is like this:
7E A0 0A 00 22 00 CB 03 93 69 CE 7E

I'd like to use GXDLMSClient to read data from the meters, but if I set the parameters like this:
GXDLMSClient client = new GXDLMSClient();
client.UseLogicalNameReferencing = true;
client.InterfaceType = InterfaceType.HDLC;
client.ClientAddress = 1;
client.ServerAddress = GXDLMSClient.GetServerAddress(17, 101);
client.ServerAddressSize = 4;

I send the SNRM request like this:
7E A0 0A 00 00 22 CB 03 93 55 0E 7E

Why is 22 value of the 4 sized server address is different?
What is the right way to handle this proble?

HorCsa

horcsa

8 years 11 months ago

I've changed the

I've changed the getServerAddress to return the bytes in the requested order and this seems to work form my application.

Profile picture for user Kurumi

Kurumi

8 years 11 months ago

GXDLMSClient Server address size 4 wrong order

Hi HorCsa,

Server address is problem with older meters. What meter you try to read?

BR,

Mikko

horcsa

8 years 11 months ago

GXDLMSClient Server address size 4 wrong order

It is an Actaris SL7000 (from 2008).

HorCsa

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Version mismatch between Gurux.DLMS 9.x and Gurux.Common/Gurux.Serial 8.x
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
More

Who's new

  • Kak_zqKr
  • Kak_maKr
  • Marciaannem
  • Scottstike
  • rcprociG
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin