L+G E355 Load Control

By DuddyS , 28 August, 2026
Forums
Gurux.DLMS

We have an L+G E355 meter with a main (primary) contactor controllable via "0.0.96.3.10.255" object/attributes that works perfectly using gxDlmsDisconnectControl.(RemoteDisconnect and RemoteReconnect).
However, the meter has also has a load control (secondary low load) relay that we are still unable to control.
Do you have any suggestion around this main contactor/load relay scenario as all the topics I have viewed seem to be related to the primary contactor and that is not our issue.
It may simply be I a, not using the correct OBIS code for this operation, but discovery of this information is very elusive.

Profile picture for user Kurumi

Kurumi

3 weeks 4 days ago

Hi, You use load control in…

Hi,

You use load control in the same way as you use "0.0.96.3.10.255". You just need to change the OBIS code to the correct one.

Read your meter with GXDLMSDirector, and you can see the correct OBIS code and also that RemoteDisconnect and RemoteReconnect are available.

Regards,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin