By Shanmukhi , 24 July, 2025
Forums
DLMSDirector

I have a doubt about the scalar part in the profile generic class. In the block load profile, for the voltage parameter, there is no decimal point displayed in the UI. As I have given the scalar part in the Scalar: block load profile parameter.

Shanmukhi

1 year 3 months ago

Scalar: block load profile…

Scalar: block load profile parameter

Shanmukhi

1 year 3 months ago

Adding screenshots for your…

Adding screenshots for your reference.

https://www.dropbox.com/scl/fi/rym2opd7tpe8hjef6lkpw/Screenshot-2025-07…

https://www.dropbox.com/scl/fi/vtuxequqqwjtln7bdc0ra/Screenshot-2025-07…

Profile picture for user Kurumi

Kurumi

1 year 3 months ago

Hi, The scaler is used if it…

Hi,

The scaler is used if it's set to the register object. If you have changed the scaler, you need to read the association view again because the scaler is static and it's read only once.

Find the register object, e.g. 1.0.12.27.0.255, and check the scaler value. In the Indian standard, scalers can be saved to a profile generic buffer. GXDLMSDirector doesn't support that feature.

BR,
Mikko

Shanmukhi

1 year 3 months ago

Even if I read for the first…

Even if I read for the first time, there is no change of decimal point. Is it compulsory that every parameter that is in the profile generic class should be mentioned in the register class?

Profile picture for user Kurumi

Kurumi

1 year 2 months ago

Hi, It's possible to save…

Hi,

It's possible to save clock, data, register, etc values to the profile generic buffer.

I can see from the pic you share that your meter is using Indian standard. If you read the register object 1.0.12.27.0.255 what is the scaler value?

It should be the same as in the screenshot (0,01).

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • Need RJ45 pin configuration for Saral 300 and Saral 305 Secure meters
  • Query Regarding Class 63 Status Mapping Support in Gurux DLMS Python
  • Inhemeter
  • DLMS Server - Profile Generic - can't add too many items to profile generic capture object - how to set maximum profile entries
  • HDLC Frames sequencing
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin