Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Failed To Receive Reply From The Device In Given Time.

Failed to receive reply from the device in given time.

By Nuruddeen , 25 November, 2024
Forums
DLMSDirector

I am trying to connect to a Shenzhen CLOU meter with Director, the Director returns Failed to receive reply from the device in given time after a while.

This is the log:

16:30:42 04:30:42.375 Info Opening
16:30:42 04:30:42.375 Info Serial Port Settings: Port Name: COM3 Baud Rate: 300 Data Bits: 7 Parity: None Stop Bits: One Flow Control: None Eop: None
16:30:42 04:30:42.442 Info Open
16:30:43 Send SNRM request.
TX: 7E A0 08 02 03 03 93 05 77 7E
16:30:43 04:30:43.458 Sent 7E A0 08 02 03 03 93 05 77 7E
16:30:48 Data send failed. Try to resend 1/3
16:30:48 04:30:48.459 Sent 7E A0 08 02 03 03 93 05 77 7E
16:30:53 Data send failed. Try to resend 2/3
16:30:53 04:30:53.459 Sent 7E A0 08 02 03 03 93 05 77 7E
16:30:58 Failed to receive reply from the device in given time.
16:30:58 Send Disconnect request.
TX: 7E A0 08 02 03 03 53 09 B1 7E
16:30:58 04:30:58.460 Sent 7E A0 08 02 03 03 53 09 B1 7E
16:31:03 Data send failed. Try to resend 1/3
16:31:03 04:31:03.461 Sent 7E A0 08 02 03 03 53 09 B1 7E
16:31:08 Data send failed. Try to resend 2/3
16:31:08 04:31:08.461 Sent 7E A0 08 02 03 03 53 09 B1 7E
16:31:13 Failed to receive reply from the device in given time.
16:31:13 04:31:13.462 Info Closing
16:31:13 04:31:13.462 Info Closed

when I try the HDLC address resolver, it gives the following error: Server address search failed. Device not found

Profile picture for user Kurumi

Kurumi

1 year 8 months ago

Hi, Check your baud rate…

Hi,

Check your baud rate. Now it's 300, and I believe that your meter is using a higher baud rate. I believe that your parity is wrong. Create a new device with GXDSLMDirector, and change the interface type to HDLC try again.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200
  • Mon, 06/15/2026 - 08:52
    gurux.dlms.c 9.0.2606.1501

New forum topics

  • Service not known error on gprs communication
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin