Failed to receive reply from the device in given time.

By Nuruddeen , 25 November, 2024
Forums
DLMSDirector

I am trying to connect to a Shenzhen CLOU meter with Director, the Director returns Failed to receive reply from the device in given time after a while.

This is the log:

16:30:42 04:30:42.375 Info Opening
16:30:42 04:30:42.375 Info Serial Port Settings: Port Name: COM3 Baud Rate: 300 Data Bits: 7 Parity: None Stop Bits: One Flow Control: None Eop: None
16:30:42 04:30:42.442 Info Open
16:30:43 Send SNRM request.
TX: 7E A0 08 02 03 03 93 05 77 7E
16:30:43 04:30:43.458 Sent 7E A0 08 02 03 03 93 05 77 7E
16:30:48 Data send failed. Try to resend 1/3
16:30:48 04:30:48.459 Sent 7E A0 08 02 03 03 93 05 77 7E
16:30:53 Data send failed. Try to resend 2/3
16:30:53 04:30:53.459 Sent 7E A0 08 02 03 03 93 05 77 7E
16:30:58 Failed to receive reply from the device in given time.
16:30:58 Send Disconnect request.
TX: 7E A0 08 02 03 03 53 09 B1 7E
16:30:58 04:30:58.460 Sent 7E A0 08 02 03 03 53 09 B1 7E
16:31:03 Data send failed. Try to resend 1/3
16:31:03 04:31:03.461 Sent 7E A0 08 02 03 03 53 09 B1 7E
16:31:08 Data send failed. Try to resend 2/3
16:31:08 04:31:08.461 Sent 7E A0 08 02 03 03 53 09 B1 7E
16:31:13 Failed to receive reply from the device in given time.
16:31:13 04:31:13.462 Info Closing
16:31:13 04:31:13.462 Info Closed

when I try the HDLC address resolver, it gives the following error: Server address search failed. Device not found

Profile picture for user Kurumi

Kurumi

1 year 12 months ago

Hi, Check your baud rate…

Hi,

Check your baud rate. Now it's 300, and I believe that your meter is using a higher baud rate. I believe that your parity is wrong. Create a new device with GXDSLMDirector, and change the interface type to HDLC try again.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • JASA SERVICE/SERVICE MEJA BILLIARD BONGKAR PASANG | WA 083148835648
  • ISAK Billiard Sports PIK2 | WA 083148835648
  • Akusara Billiard Tangerang | WA 083148835648
  • Sumo Balls Pro Billiards | WA 083148835648
  • Dobilliard | WA 083148835648
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin