Hi,
I'm trying to read load profile of a Landis+Gyr e570 using GXDLMSDirector. I can read objects from the meter without any problems, but when I tries read load profile, I only get the logs below. I use the time interval function.
GXDLMSDirector 9.0.2409.2501
Log created 21:48:57
21:49:06 Read object type ProfileGeneric index: 4
7E A0 14 00 02 84 D1 41 90 30 73 E6 E6 00 05 01 02 0B 80 88 F3 7E
21:49:06
7E A0 17 41 00 02 84 D1 38 99 27 E6 E7 00 0C 01 00 06 00 00 03 84 AE 6B 7E
21:49:06 Read object type ProfileGeneric index: 5
7E A0 14 00 02 84 D1 41 B2 20 71 E6 E6 00 05 01 02 0B 88 C0 7F 7E
21:49:06
7E A0 14 41 00 02 84 D1 5A E3 CF E6 E7 00 0C 01 00 16 04 44 6F 7E
21:49:06 Read object type ProfileGeneric index: 6
7E A0 14 00 02 84 D1 41 D4 10 77 E6 E6 00 05 01 02 0B 90 09 E3 7E
21:49:06
7E A0 24 41 00 02 84 D1 7C 9D 5D E6 E7 00 0C 01 00 02 04 12 00 08 09 06 00 00 01 00 00 FF 0F 02 12 00 00 95 CD 7E
21:49:06 Read object type ProfileGeneric index: 7
7E A0 14 00 02 84 D1 41 F6 00 75 E6 E6 00 05 01 02 0B 98 41 6F 7E
21:49:07
7E A0 17 41 00 02 84 D1 9E A5 E7 E6 E7 00 0C 01 00 06 00 00 1B 30 50 C3 7E
21:49:07 Read object type ProfileGeneric index: 8
7E A0 14 00 02 84 D1 41 18 70 7B E6 E6 00 05 01 02 0B A0 8A D2 7E
21:49:07
7E A0 17 41 00 02 84 D1 B0 D9 2F E6 E7 00 0C 01 00 06 00 00 2A C2 B7 B8 7E
What could be the cause of this problem and how to read the load profile of this meter?
Hi, You are not reading theā¦
Hi,
You are not reading the buffer. Select the profile generic that you try to read and then select "Access rights" tab. What are the access levels of the buffer and capture objects?
BR,
Mikko