Hi,
I`m reading register 1.0.1.8.0.255, but no response from device received.
[TraceRX] 7EA01A02DF6132071DE6E600C001C100030100010800FF020032687E
[TraceRX] 7EA0086102DF1171C07E
Please tell me what this means?
Can I determine that the session is closed and not read the next object?
Thank you
Hi, The meter asks the next…
Hi,
The meter asks the next part of the client data and this is wrong because all the data is already sent. I believe that the meter has terminated the connection.
BR,
Mikko