Not able to read rows by range

By ParthDesai , 23 July, 2024
Forums
General discussion

Hello,

I am not able to read rows by range using C.

int ret;
unsigned char logical_name[6];
gxtime startTime;
gxtime endTime;
gxProfileGeneric bufferDataByDateTimeRange;
time_init3(&startTime, 2024, 07, 23, 19, 0, 0, 0);
time_init3(&endTime, 2024, 07, 23, 19, 30, 0, 0);
ret = com_open(connection, port);
printf("Error (If Any): %s\n", hlp_getErrorMessage(ret));
ret = com_initializeConnection(connection);
printf("Error (If Any): %s\n", hlp_getErrorMessage(ret));
hlp_setLogicalName(logical_name, "1.0.99.1.0.255");
cosem_init2((gxObject*)&bufferDataByDateTimeRange, DLMS_OBJECT_TYPE_PROFILE_GENERIC, logical_name);
ret = com_read(connection, (gxObject*)&bufferDataByDateTimeRange, 3);
printf("Error (If Any): %s\n", hlp_getErrorMessage(ret));
ret = com_getAssociationView(connection, outputFile);
ret = com_readRowsByRange(connection, &bufferDataByDateTimeRange, &startTime.value, &endTime.value);

printf("Error (If Any): %s\n", hlp_getErrorMessage(ret));
printf("ReadRowsByRange: %d\n", ret);
com_close(connection);
con_close(connection);

root@SP1002:~/GuruxDLMS.c-master/GuruxDLMSClientExample/bin# sudo ./gurux.dlms.client.bin -S /dev/ttyO5 -c 32 -s 1 -a Low -P lnt1 -t Verbose -g "1.0.99.1.0.255:2"
Error (If Any): OK
InitializeConnection

TX: 7E A0 07 03 41 93 5A 64 7E

RX: 7E A0 1E 41 03 73 8E 7F 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

TX: 7E A0 40 03 41 10 5F 93 E6 E6 00 60 32 A1 09 06 07 60 85 74 05 08 01 01 8A 02 07 80 8B 07 60 85 74 05 08 02 01 AC 06 80 04 6C 6E 74 31 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 40 1E 1D FF FF 1B E5 7E

RX: 7E A0 37 41 03 30 21 79 E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 10 1C 04 00 00 07 06 94 7E
Error (If Any): OK

TX: 7E A0 19 03 41 32 3A BD E6 E6 00 C0 01 C1 00 07 01 00 63 01 00 FF 03 00 8C 90 7E

RX: 7E A8 89 41 03 52 CB AC E6 E7 00 C4 01 C1 00 01 13 02 04 12 00 08 09 06 00 00 01 00 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 0E 1B 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 20 1B 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 34 1B 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 48 1B 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 01 1D 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 10 1D 7E C2 7E

TX: 7E A0 07 03 41 51 44 81 7E

RX: 7E A8 89 41 03 54 FD C9 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 02 1D 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 05 1D 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 06 1D 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 07 1D 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 08 1D 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 09 1D 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 0A 1D 00 FF 9A DA 7E

TX: 7E A0 07 03 41 71 46 A0 7E

RX: 7E A0 68 41 03 56 FE 18 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 1F 1B 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 33 1B 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 47 1B 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 5E 5B 01 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 00 5E 5B 02 FF 0F 02 12 00 00 3A 3F 7E
Error (If Any): OK

TX: 7E A0 4C 03 41 94 47 C6 E6 E6 00 C0 01 C1 00 07 01 00 63 01 00 FF 02 01 01 02 04 02 04 12 00 08 09 06 00 00 01 00 00 FF 0F 02 12 00 00 09 0C 07 E8 07 15 07 00 00 00 00 00 00 00 09 0C 07 E8 07 15 07 0A 27 24 00 00 00 00 01 00 A9 5F 7E

Data send failed. Try to resend 1/3

Data send failed. Try to resend 2/3

Data send failed. Try to resend 3/3

ReadObject failed Data receive failed.
Error (If Any): Data receive failed.
ReadRowsByRange: 253

TX: 7E A0 11 03 41 B6 CE 9A E6 E6 00 62 03 80 01 00 BD 9B 7E

RX: 7E A0 07 41 03 51 5C 47 7E

TX: 7E A0 07 03 41 53 56 A2 7E

RX: 7E A0 1E 41 03 73 8E 7F 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
Data receive failed.

Profile picture for user Kurumi

Kurumi

1 year 12 months ago

Hi, Check what time zone…

Hi,

Check what time zone your meter is using. Some meters expect that the time zone is the same when readRowsByRange is used.

Try to read the meter with GXDLMSDirector first. Some meters don't implement read-by range at all.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232