Hello sir
PUSH authentication is not working
Logs and refrence image is attached
Please provide a solution

20:11:53 Send SNRM request.
TX: 7E A0 07 03 21 93 0F 01 7E
20:11:53
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
20:11:53 Send AARQ request.
TX: 7E A0 2B 03 21 10 FB AF E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 62 1E 5D FF FF 88 55 7E
20:11:54
RX: 7E A0 37 21 03 30 6C 7C E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 00 10 02 00 00 07 1C EA 7E
20:11:54
RX: 7E A0 15 21 03 52 5D 8A E6 E7 00 C4 01 C1 00 06 00 00 00 00 7D 18 7E
20:11:54 Disconnect request
TX: 7E A0 07 03 21 53 03 C7 7E
20:11:54
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
20:11:54 Send SNRM request.
TX: 7E A0 07 03 21 93 0F 01 7E
20:11:54
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
20:11:54 Send AARQ request.
TX: 7E A0 6B 03 21 10 4C B9 E6 E6 00 60 5D A1 09 06 07 60 85 74 05 08 01 03 A6 0A 04 08 71 77 65 72 74 79 75 69 8A 02 07 80 8B 07 60 85 74 05 08 02 02 AC 12 80 10 36 44 59 5C 6A 41 41 66 40 37 5D 3C 5C 6E 77 24 BE 23 04 21 21 1F 30 00 00 00 01 34 69 6E 7E 1F 93 97 5A 7D 5E C2 57 45 D1 C6 67 DD DF 81 65 C1 14 04 E2 7A E6 83 7E 7E
20:11:54
RX: 7E A0 25 21 03 30 BB 86 E6 E7 00 61 17 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 01 A3 05 A1 03 02 01 0D AE 4F 7E
20:11:54
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

Image
Profile picture for user Kurumi

Kurumi

2 years ago

Hi, Your client's address is…

Hi,

Your client's address is wrong. You try to use the Public client address (0x10).

BR,
Mikko

shagufta

2 years ago

Thanks for the response sir …

Thanks for the response sir ,
As you have mentioned we are using same client address 0x10 please check the attached refrence image and provide a solution

Image
Profile picture for user Kurumi

Kurumi

2 years ago

Hi, In Indian standard, the…

Hi,

In Indian standard, the Push client address is 0x40, not 0x10.
Select different authentication level and then select Push again.
It's automatically updated to 0x40.

BR,
Mikko

shagufta

2 years ago

Thanks for your response sir…

Thanks for your response sir,
I have changed the client address to 0x40, but still no luck ...
Please cheack the application mechanism which has written for push is correct or not ?
PS:
const U8 Authentication_Mechanism_Name_PUSH[]={0x60 ,0x85 ,0x74 ,0x05 ,0x08 ,0x02 ,0x00}; //Mechanism name for the PUSH Association

Profile picture for user Kurumi

Kurumi

2 years ago

Hi, 0x60 ,0x85 ,0x74 ,0x05 …

Hi,

0x60 ,0x85 ,0x74 ,0x05 ,0x08 ,0x02 ,0x00 means that authentication is not used, but that breaks the Indian standard. You need to ask the meter manufacturer how they have implemented this.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200
  • Mon, 06/15/2026 - 08:52
    gurux.dlms.c 9.0.2606.1501

New forum topics

  • Service not known error on gprs communication
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin