Hi Mr.Kurumi.
Please can I use this Optical head(picture below) to read smart meter (EMH) on Android (Gurux.DLMS.Android)?
If yes, what settings shoud I change.
Note: - This optical head is working fin on Windows(GXDLMSDirector).
- I'can read the same meter with another optical head(CP2101).
Thank you in advance.
Best regards.
Forums
Prblem solved. Change…
Problem solved.
Change product ID: 24597 instead of 24557.
Thank you so much.
Hi, I'm sorry for the slow…
Hi,
I'm sorry for the slow reply. Yesterday was a public holiday in Finland.
Was the problem that the wrong Chipset was identified? Did you change isUsing method?
if ((vendor == 1027 && product == 24557) ||
to
if ((vendor == 1027 && product == 24597) ||
Let me know and this can be updated to the GitHub so it doesn't cause problems to you in the future.
BR,
Mikko
Hi, Mr. Kurumi. First, Happy…
Hi, Mr. Kurumi.
First, Happy Holiday.
Yes, exacltly.
But... I still have the same problem with another Chip: QinHeng Electronics CH340 (IDV: 6790 IDP: 29987).
Is there any suggestion?
Thank you so much.
Hi, We also add support for…
Hi,
We also add support for QinHeng Electronics. The new version is released today.
BR,
Mikko
Hi, The version 2.0.4 has…
Hi,
The version 2.0.4 has been released. We don't have the QinHeng Electronics USB converter, so it couldn't be tested.
BR,
Mikko