i am connecting from Android
i am using
BSC12X1 - Optical Probe
and FT232R Serical (UART) IC MODEL
Tx: 7E A0 1F 03 21 93 76 27 81 80 13 05 01 80 06 02 02 00 07 04 00 00 00 01 08 04 00 00 00 01 B4 F9 7E
Rx: 7E A0 1F 21 03 73 78 66 81 80 13 05 02 01 00 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 FD FE 7E
Tx: 7E A0 2B 03 21 10 FB AF E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 42 1E 5D FF FF 19 35 7E
Rx: 7E A0 37 21 03 30 6C 7C E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 00 10 02 26 00 07 FE 3F 7E
Tx: 7E A0 19 03 21 32 6F D8 E6 E6 00 C0 01 C1 00 01 00 00 2B 01 03 FF 02 00 B0 AA 7E
Rx: 7E A0 15 21 03 52 5D 8A E6 E7 00 C4 01 C1 00 06 00 0F 56 4F 6E 6F 7E
Tx: 7E A0 11 03 21 54 87 3B E6 E6 00 62 03 80 01 00 BD 9B 7E
Rx: 7E A0 11 21 03 74 85 BC E6 E7 00 63 03 80 01 00 2C 0F 7E
Tx: 7E A0 07 03 21 53 03 C7 7E
Rx: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
Tx: 7E A0 1F 03 61 93 10 61 81 80 13 05 01 80 06 02 02 00 07 04 00 00 00 01 08 04 00 00 00 01 B4 F9 7E
Hi, You can read theā¦
Hi,
You can read the invocation counter from the meter and then you send SNRM message, but you don't receive UA message. Is the problem that you can't establish a secured connection to the meter?
BR,
Mikko