Reconnection Problem

By amal , 12 March, 2024
Forums
DLMSDirector

When I try to connect Gurux with smart energy meter, initially it connect. But when i disconnect and try to connect again it won't connect.

In order to reconnect again either i need to restart the meter or gurux.

I'm using both gprs and optical for connection, issue found in both.

amal

2 years 2 months ago

I can establish connection…

I can establish connection after waiting for 1 min.

When I check the data packets using wireshark, it is observed that when we try to reconnect immediately, the tcp connection packet is sent succefully [ SYN , SYN ACK, ACK] and after that it terminates the connection[ FIN ACK].

But if i wait for 1 mint and try to reconnect, there is no problem.

Why is so happening? Is this problem with client or server?

Thanks and Regards

Profile picture for user Kurumi

Kurumi

2 years 2 months ago

Hi, Please, don't add…

Hi,
Please, don't add pictures from Wireshark. They are impossible to read and don't give any information.

Check that you are sending the release message when disconnecting.
Some meters expect you to wait for a while before connecting again.

BR,
Mikko

amal

2 years 2 months ago

Hi, Thankyou for your…

Hi,

Thankyou for your response

I have checked release message when disconnecting.

From wireshark following obsevations are seen during disconnection;

* Client send FIN ACK to server
* server ACK to client
* server send FIN ACK to client
* client send ACK

After this, when i try to reconnect without waiting connection is not established.

Can i know that 1 min delay before reconnection is from client side or server side?

Thanks and Regards
Amal

Profile picture for user Kurumi

Kurumi

2 years 2 months ago

Hi, This is the server-side…

Hi,

This is the server-side limitation. As I told you before some meters expect it, but most of the meters do not need it.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin