Greetings,
When I query the time and date of the meter using GXDLMSClock() everything works as expected, since this meter is parameterized with UTC time -5 it is used:
client.useUtc2NormalTime = True
System Time: 09/22/23 15:00:31
Meter Time: 09/22/23 15:00:30
It works perfect.
but when I read the load profile the data comes with -1 day
0 1 2 3 4 5
09/21/23 13:15:00 0 0.00 0.00 0.00 0.00
09/21/23 13:30:00 0 0.00 0.00 0.00 0.00
09/21/23 13:45:00 0 0.00 0.00 0.00 0.00
09/21/23 14:00:00 0 0.00 0.00 0.00 0.00
09/21/23 14:15:00 0 0.00 0.00 0.00 0.00
09/21/23 14:30:00 0 0.00 0.00 0.00 0.00
09/21/23 14:45:00 0 0.00 0.00 0.00 0.00
09/21/23 15:00:00 0 0.00 0.00 0.00 0.00
What I get from the log is the following:
TX: 15:10:35 7E A0 08 02 C9 21 93 66 1E 7E
RX: 15:10:36 7E A0 21 21 00 02 00 C9 73 A4 E6 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
TX: 15:10:36 7E A0 2C 02 C9 21 10 74 E5 E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 00 1 E 5D FF FF B3 E2 7E
RX: 15:10:36 7E A0 3A 21 00 02 00 C9 30 70 55 E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 10 1C 00 80 00 07 06 EA 7E
TX: 15:10:36 7E A0 1A 02 C9 21 32 2D 08 E6 E6 00 C0 01 C1 00 01 00 00 2A 00 00 FF 02 00 12 80 7E
RX: 15:10:36 7E A0 25 21 00 02 00 C9 52 59 B9 E6 E7 00 C4 01 C1 00 09 10 53 45 43 30 31 32 32 31 31 41 32 38 36 2D 30 31 23 EE 7E
TX: 15:10:36 7E A0 1A 02 C9 21 54 1D 0E E6 E6 00 C0 01 C1 00 08 00 00 01 00 00 FF 02 00 60 1A 7E
RX: 15:10:37 7E A0 21 21 00 02 00 C9 74 1B 92 E6 E7 00 C4 01 C1 00 09 0C 07 E7 09 16 05 0F 0A 23 23 FE D4 00 44 D5 7E
TX: 15:10:37 7E A0 1A 02 C9 21 76 0D 0C E6 E6 00 C0 01 C1 00 07 01 00 63 01 00 FF 03 00 8C 90 7E
RX: 15:10:37 7E A0 81 21 00 02 00 C9 96 99 B3 E6 E7 00 C4 01 C1 00 01 06 02 04 12 00 08 09 06 00 00 01 00 00 FF 0F 02 12 00 00 02 04 12 00 01 09 06 00 00 61 61 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 01 01 1D 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 01 03 1D 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 01 02 1D 00 FF 0F 02 12 00 00 02 04 12 00 03 09 06 01 01 04 1D 00 FF 0F 02 12 00 00 8A C9 7E
TX: 15:10:37 7E A0 4D 02 C9 21 98 C3 47 E6 E6 00 C0 01 C1 00 07 01 00 63 01 00 FF 02 01 01 02 04 02 04 12 00 08 09 06 00 00 01 00 0 0FF 0F 02 12 00 00 09 0C 07 E7 09 16 05 0D 0A 25 00 04 74 00 09 0C 07 E7 09 16 05 0F 0A 25 00 04 74 00 01 00 64 E7 7E
RX: 15:10:38 7E A0 8C 21 00 02 00 C9 B8 AA 55 E6 E7 00 C4 02 C1 00 00 00 00 01 00 73 01 08 02 06 09 0C 07 E7 09 15 04 0D 0F 00 00 FE D4 80 12 00 00 17 00 00 00 00 17 33 23 71 0D 17 00 00 00 00 17 31 CE 5F 14 02 06 09 0C 07 E7 09 15 04 0D 1E 00 00 FE D4 80 12 00 00 17 0 0 00 00 00 17 33 0E 85 E4 17 00 00 00 00 17 31 F1 94 CC 02 06 09 0C 07 E7 09 15 04 0D 2D 00 00 FE D4 80 12 00 00 17 00 00 00 00 17 33 0B 42 2F 17 00 00 00 00 17 4B B4 7E
TX: 15:10:38 7E A0 14 02 C9 21 BA D5 61 E6 E6 00 C0 02 C1 00 00 00 01 51 BE 7E
RX: 15:10:38 7E A0 8C 21 00 02 00 C9 DA BE 15 E6 E7 00 C4 02 C1 00 00 00 00 02 00 73 32 1F AC D1 02 06 09 0C 07 E7 09 15 04 0E 00 00 00 FE D4 80 12 00 00 17 00 00 00 00 17 33 05 51 12 17 00 00 00 00 17 32 19 D2 FF 02 06 09 0C 07 E7 09 15 04 0E 0F 00 00 FE D4 80 12 00 0 0 17 00 00 00 00 17 32 E5 72 13 17 00 00 00 00 17 32 54 6B EE 02 06 09 0C 07 E7 09 15 04 0E 1E 00 00 FE D4 80 12 00 00 17 00 00 00 00 17 32 BF 4B EC 17 00 00 00 AF EF 7E
TX: 15:10:38 7E A0 14 02 C9 21 DC E5 67 E6 E6 00 C0 02 C1 00 00 00 02 CA 8C 7E
RX: 15:10:38 7E A0 6D 21 00 02 00 C9 FC C7 EC E6 E7 00 C4 02 C1 01 00 00 00 03 00 54 00 17 32 80 9E 48 02 06 09 0C 07 E7 09 15 04 0E 2 D 00 00 FE D4 80 12 00 00 17 00 00 00 00 17 33 13 01 9B 17 00 00 00 00 17 31 E4 0B 1E 02 06 09 0C 07 E7 09 15 04 0F 00 00 00 FE D4 80 12 00 00 17 00 00 00 00 17 33 0E BE 72 17 00 00 00 00 17 32 13 99 1A 47 40 7E
TX: 15:10:38 7E A0 08 02 C9 21 53 6A D8 7E
RX: 15:10:39 7E A0 0A 21 00 02 00 C9 73 A5 F3 7E
I appreciate your attention and look forward to your help.
Hi, The start and end dates…
Hi,
The start and end dates are set 22. For some reason meter returns data from 21th. Try to set ms to zero. If that doesn't help, ask if there is a firmware update available from the meter vendor.
BR,