Hi, Mikko!

I read CGXDLMSRegisterMonitor object.

TX: 7ea01a020161321382e6e600c0018100150000100101ff020047747e
RX: 7ea0186102015285c1e6e700c401810001010600000000facd7e

But when i try get value by attribute index 2 (thresholds array) it returns octet string instead array of DLMS_DATA_TYPE_UINT32

Is it OK?

Profile picture for user Dmitry

Dmitry

3 years 1 month ago

I think it should return…

I think it should return array like this:
in CGXDLMSRegisterMonitor::GetValue(CGXDLMSSettings& settings, CGXDLMSValueEventArg& e):

if (e.GetIndex() == 2)
{
e.SetValue(m_Thresholds);
return DLMS_ERROR_CODE_OK;
}

Profile picture for user Kurumi

Kurumi

3 years 1 month ago

Hi Dmitry, Don't use…

Hi Dmitry,

Don't use CGXDLMSRegisterMonitor::GetValue. I believe that you are reading the meter.
You can get the thresholds using GetThresholds -method.

Something like this:

CGXDLMSRegisterMonitor rm;
Read(&rm, 2);
rm.GetThresholds();

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin