There is a counter, successfully managed to connect to it through DLMS Director and read the parameters, but my program passes the authorization, but when trying to request the time - the device does not respond.
I looked through DLMS Translator - the requests are similar.
With what can it be connected? I attach the logs at the link https://drive.google.com/file/d/1YyCQWyIEUOiJoXmLafa_tpS9jMV5Ms72/view?…
The AARQ query in DLMS Director has these fields:
<ConformanceBit Name="ReservedSix" />
<ConformanceBit Name="GeneralBlockTransfer" />
<ConformanceBit Name="GeneralProtection" />
Although the responses from the device are the same in both cases.
Could this be the problem?
HI, Your data looks right,…
HI,
Your data looks right, but because request messages are missing from the GXDLMSDirector log I can't compare them.
Have you tried to read your meter with a client example?
BR,
Mikko
I do not have direct access…
I do not have direct access to the device, but the implementation of my driver is similar to your example.
I have attached full DLMS Director log - maybe it will help.
https://drive.google.com/file/d/1lpvBCFJaVplJbl4hbQzHm94zNS1V9k-I/view?…
The AARQ query in DLMS…
The AARQ query in DLMS Director has these fields:
<ConformanceBit Name="ReservedSix" />
<ConformanceBit Name="GeneralBlockTransfer" />
<ConformanceBit Name="GeneralProtection" />
Although the responses from the device are the same in both cases.
Could this be the problem?