  3. ReadObject Failed Register 1.0.1.7.0.255:2 Not Enough Memory Available

ReadObject failed Register 1.0.1.7.0.255:2 Not enough memory available

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Prakash , 28 December, 2022
Forums
Gurux.DLMS

Hi,

Every 5 secs, we read 6 registers from dlms meter (from L&T). Occasionally we
get "Not enough memory available" error:

If I close connection, com port and open again, it works. And then error
repeats after some time.
I also made following change in the code:
con_initializeBuffers(connection, 50 + 1024);

Below logs show successful packets, followed by error packets and then
successful packets after reconnect.

Please let me know how to fix the issue.

Thanks and Best regards,
Prakash

Read 21 bytes.
hex:[7e a0 13 41 03 fc fe 88 e6 e7 00 c4 01 c1 00 12 13 7e 03 94 7e ]
Read 23 bytes.
hex:[7e a0 15 41 03 1e 78 07 e6 e7 00 c4 01 c1 00 06 00 00 00 0e 03 f1 7e ]
Read 23 bytes.
hex:[7e a0 05 41 03 30 04 cf e6 e7 00 c4 01 c1 00 05 00 00 00 00 b1 05 7e ]

dlms data send failed. try to resend 1/3
Read 9 bytes.
hex:[7e a0 07 41 03 31 5a 24 7e ]
ReadObject failed Register 1.0.1.7.0.255:2 Not enough memory available.
com_readValue failed: 260

Read 21 bytes.
hex:[7e a0 13 41 03 52 8a c4 e6 e7 00 c4 01 c1 00 12 60 f7 66 57 7e ]
Invalid frame 52. Expected 30.

dlms data send failed. try to resend 1/3
Read 9 bytes.
hex:[7e a0 07 41 03 51 5c 47 7e ]
ReadObject failed Register 1.0.12.7.0.255:2 Not enough memory available.
com_readValue failed: 260

Read 21 bytes.
hex:[7e a0 13 41 03 74 be 80 e6 e7 00 c4 01 c1 00 12 61 15 a2 8a 7e ]
Invalid frame 74. Expected 30.

dlms data send failed. try to resend 1/3
Read 9 bytes.
hex:[7e a0 07 41 03 71 5e 66 7e ]
ReadObject failed Register 1.0.12.7.0.255:2 Not enough memory available.
com_readValue failed: 260

Read 21 bytes.
hex:[7e a0 13 41 03 96 a2 44 e6 e7 00 c4 01 c1 00 12 61 10 0f dd 7e ]
Invalid frame 96. Expected 30.

dlms data send failed. try to resend 1/3
Read 9 bytes.
hex:[7e a0 07 41 03 91 50 81 7e ]
ReadObject failed Register 1.0.12.7.0.255:2 Not enough memory available.
com_readValue failed: 260

Read 32 bytes.
hex:[7e a0 1e 41 03 73 8e 7f 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08
04 00 00 00 01 53 3b 7e ]
reconnecting dlms meter
connecting to meter ...
InitializeConnection
Read 32 bytes.
hex:[7e a0 1e 41 03 73 8e 7f 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08
04 00 00 00 01 53 3b 7e ]
Read 57 bytes.
hex:[7e a0 37 41 03 30 21 79 e6 e7 00 61 29 a1 09 06 07 60 85 74 05 08 01 01
a2 03 02 01 00 a3 05 a1 03 02 01 00 be 10 04 0e 08 00 06 5f 1f 04 00 00 10 14
02 00 00 07 bc 85 7e ]
connected to meter...
Read 21 bytes.
hex:[7e a0 13 41 03 52 8a c4 e6 e7 00 c4 01 c1 00 12 61 15 a2 8a 7e ]
Read 21 bytes.
hex:[7e a0 13 41 03 74 be 80 e6 e7 00 c4 01 c1 00 12 00 05 ae e6 7e ]
Read 20 bytes.
hex:[7e a0 12 41 03 96 19 58 e6 e7 00 c4 01 c1 00 0f 00 9a 42 7e ]
Read 21 bytes.

Profile picture for user Kurumi

Kurumi

3 years 5 months ago

Hi,

Hi,

The meter is asking for the next frame. I can't say why, because there are no read requests. This might be a random meter issue. I propose that when this happens you close the connection and read the values again.

BR,
Mikko

Prakash

3 years 5 months ago

Hi Mikko,

Hi Mikko,

Thanks for the reply.
We've implemented your suggestion. The problem occurs often. We'll contact the manufacturer for any solution.

Thanks,
Prakash

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin