By tamir , 4 May, 2021
Forums
General discussion

Hello,
I am getting a data over RS485 interface in IEC-62056-21 protocol on elster A1140 smart meter. But i get this random generated key from the meter and it hashed with the remote password i put in which is 00000000 and then it sends the hashed password to the meter. I followed bunch of examples in the internet but no success unfortunately. Please help me on this issue. I have put the received frame and the received key and generated password.
example 1:
B0A692CB07930FD1 > this is the received key
61F79994CB6EAD8E > this is the generated password
example 2:
EA864EBC197ED3D3 > this is the received key
BD73F17DA6F4D7BA > this is the generated password

this is the overall frame i am receiving.
Logon
COM3-> /?094!<CR><LF>
<-COM3 /GEC5120510070213@000<CR><LF>
COM3-> <ACK>056<CR>
COM3-> <LF>
<-COM3 <SOH>P0<STX>(FD04BE65D6157FA9)<ETX><GS>
COM3-> <SOH>P2<STX>(0000000000000000)<ETX>b
<-COM3 <ACK>
COM3-> <SOH>R1<STX>798001(10)<ETX>e
<-COM3 <STX>(30303030303030303035303734343934)<ETX><CR>
COM3-> <SOH>R1<STX>795001(08)<ETX>a
<-COM3 <STX>(505F323238303532)<ETX>{
COM3-> <SOH>P2<STX>(669A287D6388D770)<ETX><DC2>
<-COM3 <ACK>
COM3-> <SOH>W1<STX>576001(456C73746572202020202020)<ETX><SYN>
<-COM3 <ACK>

tamir

5 years 1 month ago

please help me!

please help me!

Zoljargal

5 years 1 month ago

I have a same problem!, I'm

I have a same problem!, I'm trying to do A1700's hash algorithm but it not works on A1140.

Profile picture for user Kurumi

Kurumi

5 years 1 month ago

Hi,

Hi,

Have you tried this formula to count the hash?
http://www.gurux.fi/node/5415

This is the problem with IEC 62056-21. The standard doesn't define how password hash is counted and different manufacturers are using different ways to use it. Some meters are expecting plain passwords.

BR,
Mikko

tamir

5 years 1 month ago

yeah. i tried that formula.

yeah. i tried that formula. we could not get the same answer. Can you maybe use the formula and calculate it to see if you can get the same answer? if i use different password than 00000000 it causes NAK.

Profile picture for user Kurumi

Kurumi

5 years 1 month ago

Hi,

Hi,

There is no Elster A1140 in the office and it's have been so long time when Elster was last time read,
so I'm sorry to say that I can't help you with this.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin