We downloaded the latest release of the GXDLMSDirector. We have 3 points to highlight:
1- We noticed that you added the button reset for the object "OFDM PLC MAC network administration data" so we tried to trigger it, it is giving "Object reference not set to an instant of an object" not sure if it is a problem from the client or server side
2- We are trying to read the register activation object, the assignment list is showing normally but the mask list including the active mask is not showing. We even tried to add to the mask list nothing is appearing. It is staying blank whatever we are trying to read. We are probably sure that it is a problem from the client side.
3- We noticed that in the addDevice in the interface you added the plc and the plcHdlc interface but there is nothing concerning the raw data. Was it added in this release? If yes how do we trigger it? and if not when do you intend to add this feature?
#1. You are right on this. This is now fixed and the new version is released today.
#2. I'll check this.
#3. addDevice is called from PLC after the user has found the devices and wants to add a new device. So used will tricker it.
I believe that we are talking about different things. I believe that with addDevice you mean that there is no PDU (raw) Interface available in the Interfaces list. Is this the case?
We noticed a possible improvement you can add to the GXDLMSDirector before the next release. In fact,
we tried to work with the activity calendar object especially with the passive calendar. The passive day profile was totally empty so we tried to "Add day" by adding a day Id but the button responsible to write was still grey so we were not able to trigger the write operation to the server.
But we test if initially the passive day profile is not empty we were able to add new day id. Then we tried to remove all the day Id then we tried again to add again a new day Id the same issue described above is repeated.
Hi Lara,
Hi Lara,
Thank you for pointing this out.
#1. You are right on this. This is now fixed and the new version is released today.
#2. I'll check this.
#3. addDevice is called from PLC after the user has found the devices and wants to add a new device. So used will tricker it.
BR,
Mikko
Hi Lara,
Hi Lara,
#2 This is fixed. Get the latest version.
BR,
Mikko
Hi Mikko,
Hi Mikko,
We downloaded the latest version and the #1 and #2 are both solved.
Concerning the #3 (support of raw data "plain pdu"), we didn't understand what are we supposed to do if you please explain more.
We thought that you will add in the list of the interface a new one named "plain pdu" so we can select it and use it.
Best Regards,
Lara Wakim
Hi Lara,
Hi Lara,
I believe that we are talking about different things. I believe that with addDevice you mean that there is no PDU (raw) Interface available in the Interfaces list. Is this the case?
BR,
Mikko
Hi Mikko,
Hi Mikko,
Yes this is exactly what we meant. Will you add this feature?
Best Regards,
Lara Wakim
Hi,
Hi,
THe next version is released in begin of January.
BR,
Mikko
Hello,
Hello,
We noticed a possible improvement you can add to the GXDLMSDirector before the next release. In fact,
we tried to work with the activity calendar object especially with the passive calendar. The passive day profile was totally empty so we tried to "Add day" by adding a day Id but the button responsible to write was still grey so we were not able to trigger the write operation to the server.
But we test if initially the passive day profile is not empty we were able to add new day id. Then we tried to remove all the day Id then we tried again to add again a new day Id the same issue described above is repeated.
Best Regards,
Lara Wakim
Hi Mikko,
Hi Mikko,
What are the updates concerning the new version of the GXDLMSDirector especially the implementing of the plain pdu?
Best Regards,
Lara Wakim