By Bhaumik , 8 September, 2020
Forums
Gurux.DLMS

Hi Mikko,

After doing the connect/disconnect load and getting push event from meter.

I have configured the following properties of the Client to decode and parse push events.

Client.Ciphering.SystemTitle
Client.Ciphering.AuthenticationKey
Client.Ciphering.BlockCipherKey

But, From Client.GetData(eventsData, replyData, notify) got following error:

"Data is ciphered using different security level. Actual: 48. Expected: 0"

Can you please provide an update on this ?

Profile picture for user Kurumi

Kurumi

6 years ago

Hi,

Hi,

This is updated and the security level isn't checked if it's not set.
Get the latest version.

BR,
Mikko

Bhaumik

6 years ago

Hi Mikko,

Hi Mikko,

Using the latest source and by setting the Security and Server system title, Able to decode and parse push notification.

Thanks.

Profile picture for user Kurumi

Kurumi

6 years ago

Hi,

Hi,

Thanks for this info.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • Anaglyfos Trading CC
  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin