Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Forums
  3. Improper Profile Generic Response

Improper profile generic response

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Bhaumik , 20 August, 2020
Forums
Gurux.DLMS

Mikko,

I was reading all Block load profile data from IS15959-2 meter.

Randomly, in any block got "7EA00761031F1DEF7E" response. And after that meter send this response in subsequent requests.

Can you please provide any suggestion on it?

Profile picture for user Kurumi

Kurumi

5 years 9 months ago

Hi,

Hi,

Your meter is sending a Disconnect Mode response. For some reason, your meter can't communicate with the client anymore. The reason might be that the meter needs to do something important and the meter closes the connection. Or then client has close the connection.

You can try to read a smaller amount of the data at once from the meter. There is nothing else that you can do for it.

BR,
Mikko

Bhaumik

5 years 9 months ago

Mikko,

Mikko,

Thanks for the information.

As you said "You can try to read a smaller amount of the data at once from the meter", In that case, suppose I read 50 entries from the meter.

After reading 45 entries from the meter, Meter send Disconnect mode response. So next time I have to read 50 entries again.

Is there anything that we can store all read entries somewhere, Or whatever has been received can be parse. So, from next, we can start to read from 46 to 50 entries only.

Profile picture for user Kurumi

Kurumi

5 years 9 months ago

Hi,

Hi,

The easiest way might be if you can read max 40 entries at the time. Gurux.DLMS.Net library supports parsing from the fly and you don't need to receive all the data. What programming language you are using?

BR,
Mikko

Bhaumik

5 years 9 months ago

Hi Mikko,

Hi Mikko,

I am using C# programming language.

Profile picture for user Kurumi

Kurumi

5 years 9 months ago

Hi,

Hi,

We'll try to find time after this week if we can make example of how you can do this.

BR,
Mikko

Bhaumik

5 years 9 months ago

Mikko, Thanks for the update.

Mikko,
Thanks for the update.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin