Mikko,

I was reading all Block load profile data from IS15959-2 meter.

Randomly, in any block got "7EA00761031F1DEF7E" response. And after that meter send this response in subsequent requests.

Can you please provide any suggestion on it?

Profile picture for user Kurumi

Kurumi

6 years 2 months ago

Hi,

Hi,

Your meter is sending a Disconnect Mode response. For some reason, your meter can't communicate with the client anymore. The reason might be that the meter needs to do something important and the meter closes the connection. Or then client has close the connection.

You can try to read a smaller amount of the data at once from the meter. There is nothing else that you can do for it.

BR,
Mikko

Bhaumik

6 years 2 months ago

Mikko,

Mikko,

Thanks for the information.

As you said "You can try to read a smaller amount of the data at once from the meter", In that case, suppose I read 50 entries from the meter.

After reading 45 entries from the meter, Meter send Disconnect mode response. So next time I have to read 50 entries again.

Is there anything that we can store all read entries somewhere, Or whatever has been received can be parse. So, from next, we can start to read from 46 to 50 entries only.

Profile picture for user Kurumi

Kurumi

6 years 2 months ago

Hi,

Hi,

The easiest way might be if you can read max 40 entries at the time. Gurux.DLMS.Net library supports parsing from the fly and you don't need to receive all the data. What programming language you are using?

BR,
Mikko

Bhaumik

6 years 2 months ago

Hi Mikko,

Hi Mikko,

I am using C# programming language.

Profile picture for user Kurumi

Kurumi

6 years 2 months ago

Hi,

Hi,

We'll try to find time after this week if we can make example of how you can do this.

BR,
Mikko

Bhaumik

6 years 2 months ago

Mikko, Thanks for the update.

Mikko,
Thanks for the update.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • Need RJ45 pin configuration for Saral 300 and Saral 305 Secure meters
  • Query Regarding Class 63 Status Mapping Support in Gurux DLMS Python
  • Inhemeter
  • DLMS Server - Profile Generic - can't add too many items to profile generic capture object - how to set maximum profile entries
  • HDLC Frames sequencing
More

Who's new

  • Asier Sierra
  • BlessyAnn
  • sravya.thota@m…
  • Diwakar
  • williamorussell
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin