By lhein , 17 July, 2019
Forums
DLMSDirector

Hello I'm trying to connect to a Calin CA168 meter. Since I don't have the optical cord with me, I am connecting to the Calin DCU via RS-485. I am unable to connect to them since Calin isn't on the list of manufacturers. I also tried Gurux as a manufacturer and same problem occurred.

This is the error code I keep getting: Failed to receive a reply from the device in a given time.

Profile picture for user Kurumi

Kurumi

6 years 10 months ago

Hi,

Hi,

Select Gurux as the manufacturer and change Start protocol from "IEC" to DLMS.
Check baud rate usually that is causing the problem. It's depending on the meter type and manufacturer.
Default is 9600 8N1.

BR,

Mikko

lhein

6 years 10 months ago

In reply to Hi, by Kurumi

Yeah we have done that

Yeah we have done that already; we started with baud rate of 115200 since it's specified by the manufacturer. But we also tried with 9600. Same issue arises.

Profile picture for user Kurumi

Kurumi

6 years 10 months ago

Hi,

Hi,

Do you have an external power supply in your RS-485 converter? Are you using USB to RS-232 converter first?

BR,

Mikko

lhein

6 years 10 months ago

Hi Mikko,

Hi Mikko,
We were using RS-485 and had the meter hooked up directly to the 230V line. But we're no longer looking into this, so we won't need further assistance on debugging this.
I had another question. When I viewed the logs, it appears GXDirector sent 7E A0 07 03 21 93 0F 01 7E. I'm assuming this is in HDLC and I was wondering if there is a away for me to decode the SNRM request that's sent in HDLC.

Profile picture for user Kurumi

Kurumi

6 years 10 months ago

Hi,

Hi,

I'm glad that you solved the problem.

You can use GuruxDLMSTranslator for this:
http://www.gurux.fi/GuruxDLMSTranslator?translate=7EA0070321930F017E

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin