Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Forums
  3. Strange Counter Answer After Asking For Period With No Data

Strange counter answer after asking for period with no data

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By wojtekpilwinski , 11 March, 2019
Forums
Gurux.DLMS

Hello,
we have issue with counter ZMD DLMS communication:
Counter Number: LGZ97755421
Configuration ID: B.M3BCPTSCMDO.0459.AT0S vGsarHSP
Firmware: B31

Please follow my explanation.
If we ask the counter for data from period which has no data, counter answers as expected, that there is no data. Like that:
SENDING MESSAGE:
7E A0 47 00 02 64 2B 41 B8 1F 4F E6 E6 00 05 01 04 62 78 01
02 04 02 04 12 00 08 09 06 00 00 01 00 00 FF 0F 02 12 00 00
09 0C 07 E2 06 1E FF 00 00 00 00 80 00 FF 09 0C 07 E2 07 01
FF 00 00 00 00 80 00 FF 01 00 14 36 7E

RECEIVED MESSAGE:
7E A0 14 41 00 02 64 2B BA 34 A0 E6 E7 00 0C 01 00 01 00 F9
F1 7E

And that is great, but after then if we ask for data from next period, we receive some strange message which we don't know how to interprate. Like that:
SENDING MESSAGE:
7E A0 47 00 02 64 2B 41 B8 1F 4F E6 E6 00 05 01 04 62 78 01
02 04 02 04 12 00 08 09 06 00 00 01 00 00 FF 0F 02 12 00 00
09 0C 07 E2 07 01 FF 00 00 00 00 80 00 FF 09 0C 07 E2 07 02
FF 00 00 00 00 80 00 FF 01 00 FE 7C 7E

RECEIVED MESSAGE (WHICH WE DON'T UNDERSTAND):
7E A0 0F 41 00 02 64 2B 97 98 99 B8 AC 08 E0 09 7E

Is there anyone who could help with such issue? I can't find anything in documentation.

For any help, great thanks in advance,

Profile picture for user Kurumi

Kurumi

7 years 3 months ago

Hi,

Hi,

Meter rejects the frame. HDLC frame id is wrong. How long you are waiting between the reads?
Do you start communication again in before sending msg 2 or do you wait and try to read next part?

BR,

Mikko

wojtekpilwinski

7 years 3 months ago

Hello, thanks for your answer

Hello, thanks for your answer.
No, I do not start comunication again before next read.
Of course I can arrange that. But don’t you think it’s strange and unpropriate to start new comunication every time there is no data in some period?

Profile picture for user Kurumi

Kurumi

7 years 3 months ago

Hi,

Hi,

I don't believe that you are using our libraries.
Your HDLC frame type is wrong if you try to read your meter twice. You need to fix that.

BR,

Mikko

wojtekpilwinski

7 years 3 months ago

In reply to Hi, by Kurumi

First of all, we use our own

First of all, we use our own library.
But the point is that we don't try to read the meter twice.
First question is about first day we know that meter doesn't have any data. And answer is just like that, no data.
Next we ask the meter about the next day, next period where meter also has no data (but during the same read session). So why should we use different type of HDLC frame?

The problem doesn't exist when we ask about days where meter has data, day by day. That's the point.

Profile picture for user Kurumi

Kurumi

7 years 3 months ago

Hi,

Hi,

If you are asking next day after first day it will fail because you don't increase HDLC frame counters.
Meter rejects next frame because frame id is wrong.
http://www.gurux.fi/GuruxDLMSTranslator?translate=7EA00F410002642B97989…

BR,

Mikko

wojtekpilwinski

7 years 3 months ago

In reply to Hi, by Kurumi

I am not sure, I am new in

I am not sure, I am new in DLMS, but I think we have some misunderstanding.
You say frame id is wrong.
But there is no problem if counter has data.
We do exactly the same, and there is no problem in normal scenario.
The problem is only if counter has no data. So it looks like problem is in the counter. We make everytime exactly the same communication protocule.

Should we manualy change the frame id only in case counter has no data or what?
As I know frame id increases automaticaly everytime counter answer.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact