Hi,

I am using C++ sample application of "GuruxDLMSServerExample" and "GuruxDLMSClientExample" and trying to write a register object of "GuruxDLMSServerExample" using "GuruxDLMSClientExample" but its showing below mentioned error-

"Access error: Device reports Read-Write denied."

But I am able to reading values properly but facing problem in writing values to the register object.

I have tried connection paramerter as mentiopned below-
(1) CGXDLMSClient cl(true);

(2) CGXDLMSClient cl(true, 16, 1, DLMS_AUTHENTICATION_LOW, "Gurux",DLMS_INTERFACE_TYPE_HDLC);

(3) CGXDLMSClient cl(true, 17, 1, DLMS_AUTHENTICATION_LOW, "Gurux",DLMS_INTERFACE_TYPE_HDLC);

Kindly suggest me. What should I do?

Thanks,
Pradson

Profile picture for user Kurumi

Kurumi

7 years 5 months ago

Write register object

Hi,

You did not tell what attribute index you try to write.

You can't write anything if the authentication level is None. You can change this for the client or the server.
In GuruxDLMSServerExample find CGXDLMSBase::GetAttributeAccess.
// All writes are allowed.
return DLMS_ACCESS_MODE_READ_WRITE;

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin