hello
i want to read from one meter from dlms port (RS485) i config default setting in gurux and send connect request but in HDLC layer one problem occured . please view Log from Gurux tool . it recive UA frame but say "Failed to receive reply" and timeout
Gurux Log:
GXDLMSDirector 8.1.1805.0402
Log created 10:57:21 AM
10:57:23 AM Initializing serial connection.
10:57:23 AM 10:57:23.495 Info Opening
10:57:23 AM 10:57:23.495 Info Serial Port Settings: Port Name: COM3 Baud Rate: 9600 Data Bits: 8 Parity: None Stop Bits: One Eop: None
10:57:23 AM 10:57:23.503 Info Open
10:57:23 AM Send SNRM request.
7E A0 07 03 03 93 8C 11 7E
10:57:23 AM 10:57:23.504 Sent 7E A0 07 03 03 93 8C 11 7E
10:57:23 AM 10:57:23.550 Received 7E A0 1F 03 02 23 73 C3 71 81 80 12 05
10:57:23 AM 10:57:23.560 Received 05 01 80 06
10:57:23 AM 10:57:23.576 Received 00 01 53 3B
Data send failed. Try to resend 1/3
10:57:32 AM Data send failed.
7E A0 1F 03 02 23 73 C3 71 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
10:57:41 AM Failed to receive reply from the device in given time.
7E A0 1F 03 02 23 73 C3 71 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
10:57:41 AM Received data:
7E A0 1F 03 02 23 73 C3 71 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
10:57:41 AM Disconnect request
10:57:41 AM Send Disconnect request.
7E A0 07 03 03 53 80 D7 7E
10:57:41 AM 10:57:41.577 Sent 7E A0 07 03 03 53 80 D7 7E
10:57:41 AM 10:57:41.668 Received 7E A0 08 03
10:57:41 AM 10:57:41.684 Received 03 02 23
Data send failed. Try to resend 1/3
10:57:50 AM Data send failed.
7E A0 08 03 02 23 73 5F F5 7E
10:57:59 AM Failed to receive reply from the device in given time.
7E A0 08 03 02 23 73 5F F5 7E
10:57:59 AM Received data:
7E A0 08 03 02 23 73 5F F5 7E
10:57:59 AM 10:57:59.685 Info Closing
10:57:59 AM 10:57:59.798 Info Closed
System.TimeoutException: Failed to receive reply from the device in given time.
at GXDLMSDirector.GXDLMSDevice.InitializeConnection()
at GXDLMSDirector.MainForm.Connect(Object sender, GXAsyncWork work, Object[] parameters)
reading Meter Error
Hi,
Try to change Server address. Now it's 1. Set Logical address to 1 and physical address to 17.
BR,
Mikko
thank you for your respons it
thank you for your respons it was ok and worked