Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Forums
  3. HPL 3 Phase Meter Reading a OBIS Code

HPL 3 Phase Meter Reading a OBIS Code

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Goutam , 31 March, 2017
Forums
General discussion

Hi,

HPL 3 Phase meter return some value when i read the
following OBIS Codes

1) Register(0.0.0.1.2.255)
Attribute 3: Scaler: 1 Unit: NoUnit
Attribute 2: 07 E1 03 01 FF 00 00 00 00 01 4A 00

2) Data(0.0.42.0.0.255)
Attribute 2: 48 50 4C 43 54 30 35 58 58 58 30 32 20 20 20 20

Can you please tell me what the value(Attribute 2) stands for and how to convert to proper meaningful value.

Profile picture for user Kurumi

Kurumi

9 years 4 months ago

HPL 3 Phase Meter Reading a OBIS Code

Hi,

That OBIS code should be "Ch. 0 Time stamp of the most recent billing period (1) closed".
Value is string ("HPLCT05XXX02 "). If you are using Java you can convert byte array to string like this:

new String((byte[]) data.getValue());

BR,

Mikko

Goutam

9 years 4 months ago

In reply to HPL 3 Phase Meter Reading a OBIS Code by Kurumi

HPL 3 Phase Meter Reading a OBIS Code

Hi,
Using CSharp dot net.

Profile picture for user Kurumi

Kurumi

9 years 4 months ago

HPL 3 Phase Meter Reading a OBIS Code

Hi,

ASCIIEncoding.ASCII.GetString((byte[]) data.Value);

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • CTKNhZElptjSlOrpkXl
  • YCbccqfLGRMnlCWoJhXP
  • Malcolmactig
  • mhliang
  • Kevinmug
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin