By nine , 2 December, 2025

P384 Client Certificate incorrect issuer CN

Forums
DLMSDirector

We are trying to import P384 Client Digital Signature certificate to meter and we are getting OtherReason. The reproducing steps:
1. We import successfully in meter your P384 Root CA Certificate that has CN=Root CA 384.
2. We create P384 Private key and use Get Certificate.. from context menu.
3. We select Digital Signature and enter Client System Title and create certificate.
4. In Certificate tab we use Info.. from context menu.
5. In Info window it shows that Issuer CN=Root CA 256 and this is the reason meter rejects this certificate

By Administrator , 2 December, 2025

gurux.dlms.c 9.0.2512.0201

The following important issues are resolved in this version:
GX_ARRAY and GX_STRUCT must assign to pVal or VariantArray will cause warning with some compilers.

By Administrator , 2 December, 2025

GX_ARRAY and GX_STRUCT must assign to pVal or VariantArray will cause warning with some compilers.

Project
gurux.dlms.c
Status
Closed (fixed)
Priority
Normal
Category
Support request
By Jayaraj , 2 December, 2025

Confirmed push service support

Forums
DLMSDirector

Hi, Does Director support confirmed push service support to enable acknowledgement for received push messages?

Thanks,
Jayaraj

By muraligowda980… , 2 December, 2025

DLMS Stack hang during Firmware Upgrade

Forums
Gurux DLMS for ANSI C

Hi,

I am trying to update the meter firmware using GuruxDLMS.c library. I am able to establish connection with the meter in Firmware Upgrade mode. Post this, while i am trying to read Image transfer enable status, block size and image transferred block status, meter isn't responding for the one of the TX sent by stack and stack is hanging in com_read function while returning with DLMS_ERROR_CODE_RECEIVE_FAILED error.

Request you let me know what could be the reason.

Please find below details for your analysis.

By Administrator , 1 December, 2025

Gurux.DLMS.Python 1.0.193

The following important issues are resolved in this version:

fix: Notification issues fixed.

By Administrator , 1 December, 2025

fix: Notification issues fixed.

Project
Gurux.DLMS.Python
Status
Closed (fixed)
Priority
Normal
Category
Bug report
By jack 001 , 1 December, 2025

Itron SL7000 load profile return error

Forums
Gurux DLMS for ANSI C

Hi Mikko, i am back working on the itron meter data reading. I created new forum post because i can't reply on the old one. 
After trying out the update, the issue on reading Itron SL7000's load profile (0.0.99.1.0.255) still persists
- if i read capture objects first (index 3), it returns error 13 : DLMS_ERROR_CODE_ACCESS_VIOLATED
- if i read without it, it returns error 258 : DLMS_ERROR_CODE_INVALID_PARAMETER, but i can see some data in the traces, and i can use GXDLMSTranslator to translate and get the data

By Bhaumik , 27 November, 2025

Convert string to octate string

Forums
General discussion

Hi Mikko,

I have to write the following array in the meter.

<Array Qty="01">
<Array Qty="02">
<Structure Qty="02">
<OctetString Value="070000FF"/>
<OctetString Value="060000FF"/>
</Structure>
<Structure Qty="02">
<OctetString Value="080000FF"/>
<OctetString Value="090000FF"/>
</Structure>
</Array >
</Array>

By andre538 , 27 November, 2025

method call result

Forums
Gurux.DLMS

Hello Mikko,

What should I do to get method call result?
For example, object target is of GXDLMSImageTransfer type.

Let's use method 3 "image verify".
As written in BlueBook "The result of the invocation of this method may be success, temporary_failure or other_reason."

Following code works ok:
reader.readDataBlock( target.imageVerify(reader.client), reply)
How should I check that result is success, temporay failure or something else?

Is it reply.error values according to green book or something else?

Pagination

  • First page
  • Previous page
  • …
  • Page 19
  • Page 20
  • Page 21
  • Page 22
  • Page 23
  • Page 24
  • Page 25
  • Page 26
  • Page 27
  • …
  • Next page
  • Last page
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin