I am new to DLMS and so would appreciate some guidance. I have a Holley meter that I am attempting to get information from over RS-485. Using the DLMSDirector, I can connect to the meter but am getting an error when I try to read the Assosciation View with a temporary failure.
Excerpt from the log is as follows:
14:18:15 Initializing serial connection.
2:18:16 PM Send SNRM request.
7E A0 07 03 21 93 0F 01 7E
2:18:16 PM
7E A0 20 21 03 73 73 98 81 80 14 05 02 00 80 06 02 00 80 07 04 00 00 00 01 08 04 00 00 00 01 CE 6A 7E
14:18:16 Parsing UA reply succeeded.
2:18:16 PM Send AARQ request.
7E A0 2B 03 21 10 FB AF E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 62 1E 5D FF FF 88 55 7E
2:18:16 PM
7E A0 37 21 03 30 6C 7C E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 12 14 01 90 00 07 5E 21 7E
14:18:16 Parsing AARE reply succeeded.
14:18:20 --- Collecting objects. ---
2:18:20 PM Collecting objects
7E A0 19 03 21 32 6F D8 E6 E6 00 C0 01 C1 00 0F 00 00 28 00 00 FF 02 00 91 53 7E
2:18:20 PM
7E A8 89 21 03 52 86 A9 E6 E7 00 C4 02 C1 01 00 00 00 01 01 02 01 82 01 D1 02 04 12 00 01 11 00 09 06 00 00 80 81 00 FF 02 02 01 02 02 03 0F 01 16 01 00 02 03 0F 02 16 03 00 01 00 02 04 12 00 01 11 00 09 06 00 00 80 82 00 FF 02 02 01 02 02 03 0F 01 16 01 00 02 03 0F 02 16 03 00 01 00 02 04 12 00 01 11 00 09 06 00 00 80 83 00 FF 02 02 01 02 02 03 0F 01 16 01 00 02 03 0F 02 16 03 00 01 00 02 04 12 00 01 11 0E E9 7E
System.Exception: GetObjects failed. Access Error : Device reports a temporary failure.
at GXDLMSDirector.MainForm.RefreshDevice(GXDLMSMeter dev, Boolean bRefresh)
at GXDLMSDirector.MainForm.Refresh(Object sender, GXAsyncWork work, Object[] parameters)
What could be possible causes for this error?
Hi, There is an issue with…
Hi,
There is an issue with the meter data. You need to ask if there is a firmware update available that fixes this.
BR,
Mikko