HDLC test #2. Illegal frame.
TX: 7E A0 07 03 21 53 03 C7
Data send failed. Try to resend 1/3
Data send failed. Try to resend 2/3
Failed to receive reply from the device in given time.
Timeout.
HDLC test #2. Receiver Ready
TX: 7E A0 07 03 21 11 15 A6 7E
RX: 7E A0 07 21 03 11 15 00 7E
HDLC test #2. Disconnect request
TX: 7E A0 07 03 21 53 03 C7 7E
RX: 7E A0 07 21 03 73 01 40 7E
Hi,
Hi,
The default settings are re-sending the frame and it will break this test. I created an issue from this:
https://www.gurux.fi/node/17848
It's fixed for the next release.
BR,
Mikko
Okay Mikko,
Okay Mikko,
Noted!
You might also want to check the "COSEM Application test #6" as well. The LLC bytes was sent twice in the AARQ frame.
COSEM Application test #6. SNRM
TX: 7E A0 07 03 21 93 0F 01 7E
RX: 7E A0 20 21 03 73 73 98 81 80 14 05 02 00 E6 06 02 00 E6 07 04 00 00 00 01 08 04 00 00 00 01 B5 F3 7E
COSEM Application test #6. AARQ
TX: 7E A0 47 03 21 10 2B A1 E6 E6 00 E6 E6 00 60 36 A1 09 06 07 60 85 74 05 08 01 01 A2 03 04 01 44 A3 03 04 01 44 A4 03 02 01 00 A5 03 02 01 00 A8 03 02 01 00 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 60 FE DF FF FF F6 FD 7E
Failed to receive reply from the device in given time.
COSEM Application tests #6 failed. Failed to receive reply from the device in given time.
HDLC test #6. Disconnect request
TX: 7E A0 07 03 21 53 03 C7 7E
RX: 7E A0 07 21 03 73 01 40 7E
COSEM Application test #6. SNRM
TX: 7E A0 07 03 21 93 0F 01 7E
RX: 7E A0 20 21 03 73 73 98 81 80 14 05 02 00 E6 06 02 00 E6 07 04 00 00 00 01 08 04 00 00 00 01 B5 F3 7E
<a href="https://www.gurux.fi/gurux.dlms.ctt.tests#app6">COSEM Application test #6 failed.</a>
Thanks.
Paul.
Hi Paul,
Hi Paul,
This is also fixed for the next release.
BR,
Mikko