Hello

We are supposed to install an M-Bus heat/water meter in an electrical meter. And we need to add an encryption key to the electrical meter so that it can decrypt the data from the M-Bus meter. How can this be done with Gurux?

Regards
Helena

Profile picture for user Kurumi

Kurumi

9 years ago

Installing M-Bus meter with encryption

Hi,

Gurux libraries (ANSI C, ANSI C++, C# Delphi and Java) are supporting GMAC security.
This is standard security in DLMS.

Following values must be set to add GMAC ciphering.

- Block ciphering key
- Authentication key
- Security level

BR,

Mikko

AndreasAtPowel

9 years ago

Hi

Hi

Yes, we are already using GMAC security against the master meter. But our question is how do we install an M-Bus meter below the master? And how do we tell the master what encryption keys to use against the M-Bus meter? We can see that you have an object called GXDLMSMBusClient in Gurux. Are we supposed to use that object in some way?

Helena

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Landis E650 meter reading over DLMS
  • class_id = 40, version = 2, pushsetup Unparsed data frame
  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined
More

Who's new

  • Sayang
  • q80435762@gmail.com
  • ONCAK
  • Berhasil
  • ratirvivege1979
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin