Hi
I want to read profile(without parse) of ACE6000 meter, I followed the example code in:
https://github.com/Gurux/Gurux.DLMS.cpp/blob/master/GuruxDLMSClientExam…
but i was not successful.
I wrote this code:

std::string value;
std::string str;
std::string ln;
std::vector<std::pair<CGXDLMSObject*, unsigned char> > list;
CGXDLMSObjectCollection Objects;
if ((ret = GetObjects(Objects)) != 0)
{
TRACE("Initialize Connection failed %s.\r\n", CGXDLMSConverter::GetErrorMessage(ret));
return 1;
}
// Read scalers and units from the device.
for(std::vector<CGXDLMSObject*>::iterator it = Objects.begin(); it != Objects.end(); ++it)
{
if ((*it)->GetObjectType() == DLMS_OBJECT_TYPE_REGISTER ||
(*it)->GetObjectType() == DLMS_OBJECT_TYPE_EXTENDED_REGISTER)
{
list.push_back(std::make_pair(*it, 3));
}
else if ((*it)->GetObjectType() == DLMS_OBJECT_TYPE_DEMAND_REGISTER)
{
list.push_back(std::make_pair(*it, 4));
}
}

if ((ret = ReadList(list)) != 0)
{
//If readlist is not supported read in old way.
for(std::vector<CGXDLMSObject*>::iterator it = Objects.begin(); it != Objects.end(); ++it)
{
if ((*it)->GetObjectType() == DLMS_OBJECT_TYPE_REGISTER ||
(*it)->GetObjectType() == DLMS_OBJECT_TYPE_EXTENDED_REGISTER)
{
(*it)->GetLogicalName(ln);
TRACE("%s\r\n", ln.c_str());
if ((ret = Read(*it, 3, value)) != 0)
{
TRACE("Err! Failed to read register: %s", CGXDLMSConverter::GetErrorMessage(ret));
//Continue reading.
continue;
}
}
else if ((*it)->GetObjectType() == DLMS_OBJECT_TYPE_DEMAND_REGISTER)
{
(*it)->GetLogicalName(ln);
TRACE("%s\r\n", ln.c_str());
if ((ret = Read(*it, 4, value)) != 0)
{
TRACE("Err! Failed to read demand register: %s", CGXDLMSConverter::GetErrorMessage(ret));
//Continue reading.
continue;
}
}
}
}

But i cant read the profile. can you help me where is my mistake?
Thanks

Profile picture for user Kurumi

Kurumi

10 years 2 months ago

Read Profile ACE6000

Hi,

We do not have ACE 6000 in our office and I can't check this right now, but there are some issues with it.
Try to read your meter without using ReadList. Reading scalers and units will take longer when you read them one by one, but it should work with ACE 6000.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Landis E650 meter reading over DLMS
  • class_id = 40, version = 2, pushsetup Unparsed data frame
  • GXObisValueItem entries without MaskSize appear to be interpreted as bit flags
  • CheckedListBox incorrectly selects GXObisValueItem Value=0 for non-zero values
  • UIValueType=TextBox is rendered as CheckedListBox when Values are defined
More

Who's new

  • Sayang
  • q80435762@gmail.com
  • ONCAK
  • Berhasil
  • ratirvivege1979
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin