Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Descriptions No Longer Display Correct After Upgrade To GuruX 8

Descriptions no longer display correct after upgrade to GuruX 8

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Rolorob , 22 April, 2016
Forums
Gurux.DLMS

We noticed that one of the changes in the later releases of GuruX was that you have to update OBIS-code information, we now have to use the class GXDLMSConverter and call UpdateOBISCodeInformation.

We have done this, but it doesn't give back the correct subscriptions for us.

Our code: new GXDLMSConverter().UpdateOBISCodeInformation(register);

We have the following OBIS-codes that do not get the correct description:

1.1.31.7.0.255 - Ch. 1 Sum Li Active power+ (QI+QIV) Inst. value
1.1.51.7.0.255 - Ch. 1 Sum Li Active power+ (QI+QIV) Inst. value
1.1.71.7.0.255 - Ch. 1 Sum Li Active power+ (QI+QIV) Inst. value

These are all mapped to the same description that is not correct. It should not be Active Power but these are Current registers. In GuruX these descriptions were mapped correctly.

Are you aware of this issue? Maybe we can help you with these issues, but we are not sure if you accept pull-requests since the latest code does not always seem to be in GitHub, is this correct?

Thanks a lot!

Rolorob

10 years 3 months ago

(this is in regards to the

(this is in regards to the .NET code version)

Profile picture for user Kurumi

Kurumi

10 years 3 months ago

Descriptions no longer display correct after upgrade to GuruX 8

Hi,

We have changed this back. Get latest version (8.0.0.17).

BR,

Mikko

Rolorob

10 years 3 months ago

Hi Mikko,

Hi Mikko,

The latest version is 8.1.0.9 at the moment right? Are you saying that the current 8.1 branch is cancelled? Or are you saying that version 8.1.0.10 for instance will have the same way to load Obis info as 8.0.0.17?

It's currently not crucial for us that this works, but in the near future (1 to 2 months) we need this to work. So can we stay on the 8.1 branch and will the code be made available there as well?

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • T_APPL_DATA_LN_N1 subtest 3 fails on an LN-only server regardless of the response to a non-existing-object GET
  • Version mismatch between Gurux.DLMS 9.x and Gurux.Common/Gurux.Serial 8.x
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
More

Who's new

  • xoXohZoMyGaFkzBA
  • PlJWQuxCniPcQl…
  • software_P
  • eloisedc16
  • OlegVoiva
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin