By dafeng0908 , 10 March, 2016
Forums
DLMSDirector

I use Mode E protocal.
In physical.req/ind Stage, I finish handshark and enter HDLC Stage.
When I receive SNRM command, and I return RA Command.
But director show "System.IO.IOException: 裝置無法辨識命令。"

how do I trace the client.GetData(p.Reply, reply)) function to find my bug?

-----------------------------------------------------------------------------------------
//Loop until whole COSEM packet is received.
while (!client.GetData(p.Reply, reply))
{
//If Eop is not set read one byte at time.
if (p.Eop == null)
{
p.Count = 1;
}
if (!media.Receive(p))
{
//Try to read again...
if (++pos != tryCount)
{
System.Diagnostics.Debug.WriteLine("Data send failed. Try to resend " + pos.ToString() + "/3");
continue;
}
string err = "Failed to receive reply from the device in given time.";
GXLogWriter.WriteLog(err, p.Reply);
throw new Exception(err);
}
}

Profile picture for user Kurumi

Kurumi

10 years 4 months ago

Director_RA Command error

Hi,

Can you send trace to me? We can check what is wrong in your data.
You can get my contact info from here:
http://www.gurux.fi/AboutUs

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200
  • Mon, 06/15/2026 - 08:52
    gurux.dlms.c 9.0.2606.1501

New forum topics

  • Service not known error on gprs communication
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
More

Who's new

  • ksFhuuipOxKrxk…
  • sherylrk3
  • OLaneHycle
  • LxfgLnoisbruoL…
  • SunbetLith
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin