By surovsv , 9 February, 2016
Forums
DLMSDirector

Error reading.

Hi!

After installing version 8.0.0.5 can not read the answer Aare.
The parameters are the following:
-Media: Serial
-Client Address: 0x10
-Physical Server: 0x11
-Logical Server: 1

Log created 13:52:24
13:52:26 Initializing serial connection.
13:52:26 Send SNRM request.
7E A0 08 02 23 21 93 BD 64 7E
13:52:26 Received data
7E A0 1F 21 02 23 73 E6 C7 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
13:52:26 Parsing UA reply.<CR><LF>81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01
13:52:26 Parsing UA reply succeeded.
13:52:26 Send AARQ request
7E A0 2C 02 23 21 10 AF 9F E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 00 7E 1F FF FF 99 C8 7E
13:52:26 Received data
7E A0 38 21 02 23 01 3E C7 E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 30 1D 19 00 00 07 0C 52 7E
13:52:26 Parsing AARE reply<CR><LF>E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 30 1D 19 00 00 07
13:52:26 Disconnect request
7E A0 08 02 23 21 53 B1 A2 7E
13:52:27 Received data
7E A0 0A 21 02 23 0F 19 EC 47 0F 7E
System.ArgumentOutOfRangeException: Требуется неотрицательное число (It requires non-negative number).
Имя параметра (parameter name): count
в GXDLMSDirector.GXDLMSDevice.InitializeConnection() в C:\Projects\GXDLMSDirector\Development\GXDLMSDevice.cs:строка (line) 374
в GXDLMSDirector.MainForm.Connect(Control sender, Object[] parameters) в C:\Projects\GXDLMSDirector\Development\MainForm.cs:строка (line) 929

Thanks!

Profile picture for user Kurumi

Kurumi

10 years 4 months ago

AARE

Hi,

What meter you are using? AARE Frame that meter returns is not correct.
Do you remember was server side 4 bytes long earlier?

BR,

Mikko

surovsv

10 years 4 months ago

What server side 4 bytes long

What server side 4 bytes long?

Thanks!

Profile picture for user Kurumi

Kurumi

10 years 4 months ago

AARE

Hi,

Can you read your meter with older version?
If you can, can you send it's trace to me?
You can find my contact info from here:
http://www.gurux.fi/AboutUs

What meter you try to read?

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin