Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Reading Values On Elster A1800

Reading values on Elster A1800

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By jpaa07 , 13 January, 2016
Forums
DLMSDirector

Hi, I'm working with an Elster A1800 and I need to get meter information like voltaje, current, power but I don’t know if with that meter I can do this, or only I can get general information like logical name, metering points IDs, because with the DLMS Director program only show me the values on the picture, if somebody can help me I really thank you.

Profile picture for user Kurumi

Kurumi

10 years 5 months ago

Elster A1800

Hi,

First you should check those values under Register group.
Current, Voltage, etc. are usually there.

If they are not, I can check is your meter returning this data.

Can you read your meter and send log file to me?
You can get log selecting "View Log" under Tools menu.
My contact information you will find here:
http://www.gurux.fi/AboutUs

BR,

Mikko

jpaa07

10 years 5 months ago

Log view, connecting and reading Elster A1800

Hi Mikko,
I sent you an email, with the log view. I tried to send for this forum but I got blocked, I wait your answer and Thank you very much!

Profile picture for user Kurumi

Kurumi

10 years 5 months ago

Elster A1800

Hi,

I got it. Forum should not accept trace logs anymore. We have tightened Forum rules because of spam.
I'll let you know answer for tomorrow.

BR,

Mikko

jpaa07

10 years 5 months ago

In reply to Elster A1800 by Kurumi

Elster A1800

Hi Mikko,
That's sounds good, so, I will waiting your response, Thank you for your support
Best Regards,

Pablo.

jpaa07

10 years 4 months ago

In reply to Elster A1800 by Kurumi

Els

Hi Mikko, do you have a solution already?, sorry for bother you but I have a few time to do that, Thank you very much.

Profile picture for user Kurumi

Kurumi

10 years 4 months ago

Elster A1800

Hi Pablo,

We parsed the log file that you sent. There are only 16 objects and all are shown on GXDLMSDirector.

There are couple of options.
1. Elster supports only partly DLMS protocol. It supports only objects what you see at the moment with GXDLMSDirector.

2. You must use higger authentication and password to connect to the meter to see registers.

Try to change authentication to Low, Client ID to 11 and use password.

I hope this helps you,

BR,

Mikko

carlos789

9 years 2 months ago

In reply to Elster A1800 by Kurumi

A1800 Elster

Hi Mikko:
I am new to GURUX software
Could you tell me what values to place on properties, so I can communicate with an A1800.
I am using a media converter (TCP to Serial)
With the Metercat, I communicate well.
Many greetings
Carlos

Profile picture for user Kurumi

Kurumi

9 years 2 months ago

A1800 Elster

Hi,

Select "Elster Electricity LLC" as manufacturer. Then select "Net" to media and update right IP address and port number.

BR,

Mikko

carlos789

9 years 2 months ago

Hello Mikko:

Hello Mikko:
Thank you very much for your answer. Now I find myself in the same situation as ipaao7. That is expressed in the beginning. I find myself looking for the method to read the password level 1 but I am not having luck. Would you know how?
regards
Carlos

Profile picture for user Kurumi

Kurumi

9 years 2 months ago

Elster A1800

Hi,

You should ask password from the meter vendor or owner. Password is usually changed.

BR,

Mikko

carlos789

9 years ago

Hello:

Hello:
After a telephone consultation with personnel of Elster Argentina, I informed that the energy meters are not of factory, with the firmware DLMS / COSEM. For this I should expressly request this characteristic at the time the acquisition is made.
So I could not interrogate the A1800 computer with GURUX software. My big question is because I have the same screen as ipaa07, if the A1800 does not have built-in DLMS?
Many greetings
Carlos

Profile picture for user Kurumi

Kurumi

9 years ago

Elster A1800

Hi,

Our clients are reading Elster A1800 with DLMS/COSEM.
I find out that DLMS part is optional in Elster A1800 meters.
You can find more info here:

https://www.elstersolutions.com/en/product-details-all-regions/61/en/A1…;

BR,

Mikko

aboayoub

8 years 1 month ago

Update firmware version Elster A1800

Hi Mikko,

j'ai besoin de ton aide/proposions à propos le compteur ELster type A1800,
Je veut connecter le compteur via le Port RS232 ( type de compteur A1800 (model 1860RALN-X s150)) mais quand j'essaie de télécharger le Protocol de communication DLMS , l’opération échouée et un message d'erreur affiche ( Function failed , An error occurred while processing replace remote task.DLMS only protocol option is not supported bye the connected meter) :
Merci pour votre retour,

aboayoub

8 years 1 month ago

Update firmware version Elster A1800

Hi,
Est ce qu'il y a une possibilité de faire le update firmware version de Elster A1800,

crdt,

aboayoub

8 years 1 month ago

Update firmware version Elster A1800

Hi,
Est ce qu'il y a une possibilité de faire le update firmware version de Elster A1800,

crdt,

carlos789

8 years 1 month ago

Hi Aboayoub:

Hi Aboayoub:
Thanks a lot.
To update the firmware, I can do it myself or I would have to send it to the factory.?
regards
Carlos

aboayoub

8 years 1 month ago

Update firmware version Elster A1800

hi Carlos,
thank you very much firstly,

I have a meter Elster (type A1800 model A1860RALN-X S150 (firmware version 3.2))

it is already installed and in service with a transformer,
can you send me a procedure or a method to do version update, so I can configure with DLMS protocol,

BR

mbejane

7 years 7 months ago

hello

Im Mbejane.. anyone knows how to update the firmware?

we are connecting using metercat but cannot do it with director, we have an elster a1800 2010

How can we be sure that we have DLMS?
thanks

mbejane

7 years 7 months ago

metercat

This is our METERCAT info

https://imgur.com/a/Suw31sA

Profile picture for user Kurumi

Kurumi

7 years 7 months ago

Elster a1800

Hi,

DLMS support is optional for a1800. If the meter doesn't support DLMS then you can use GXDLMSDirector to update the firmware. You should check is there DLMS label on the meter cover.

BR,
Mikko

deivy311

7 years 5 months ago

configurations Parameters A1800

hi there!, I've read your post and I want to ask if you can share me the parameters that you are using to can communicate you with the A1800 meter such as physical server client and etc etc etc.

Thanks in advance :)

Profile picture for user Kurumi

Kurumi

7 years 5 months ago

Elster A1800

Hi,

Start GXDLMSDirector and select Elster Electricity LLC as a manufacturer.

BR,

Mikko

deivy311

7 years 5 months ago

In reply to Elster A1800 by Kurumi

Access Error : Device reports Read-Write denied.

Hi Kurumi;

I already connect to the meter with "low authentication" but when I try to download the dates of the generic profile it is appearing the next error "Access Error: Device reports Read-Write denied." do you know what could be happening?

Thanks in advance!

JALIL

7 years 5 months ago

In reply to Elster A1800 by Kurumi

communicating with energy meters alpha a1800 via modbus gateway

Hey ! I would be grateful if anyone could help ! I’am working on a project, the main target is communicating with 5 energy meters alpha a1800 on ethernet TCP/IP using the serial ethernet converter ( EDW-100) as a modbus gateway, all meters support DLMS protocol but iam not sure if i can use GXDLMSDirector as a modbus client to read meters data via ethernet? and if its the case what is the right device configuration to applie to the GXDLMSDirector . thank in advance

Profile picture for user Kurumi

Kurumi

7 years 5 months ago

Elster A1800

Hi,

If you want to use GXDLMSDirector you need to communicate with DLMS. GXDLMSDirector doesn't handle ModBus protocol.

BR,
Mikko

JALIL

7 years 5 months ago

architecture level and hardware components to use?

hi,
thank you very much firstly,
to be more specific how I can communicate meters throughout DLMS protocol, architecture level and hardware components to use?
(i read that i can build the AMR through either TCP/IP, Terminal or Serial connection, but what kind of hardware I need to use TCP IP solution)

JALIL

7 years 5 months ago

architecture level and hardware components

I would be garteful if you could help !
how I can communicate meters throughout DLMS protocol, architecture level and hardware components to use (the physical link serial rs485 adapter or any converter.....) ?
(i read that i can build the AMR through either TCP/IP, Terminal or Serial connection, but what kind of hardware I need to use TCP IP solution)

Profile picture for user Kurumi

Kurumi

7 years 5 months ago

communicating with energy meters alpha a1800 via modbus gateway

Hi,

Please, if you have a new question, create a new topic and don't ask the same question twice.

You can use any kind of HW you want to. It debends from the meter is meter supporting TCP/IP, serial or both.

BR,
Mikko

JALIL

7 years 4 months ago

In reply to A1800 Elster by carlos789

HELP

Hi carlos789,
i'm working in the same architecture as you but even metercat is not working, i would like to have your feedback about the converter setting to communicat metercat to elster A1800.how i can contact can directly ?

ELMIR

6 years ago

Dear friend,

Dear friend,

I can't read Elster A1800 via DLMSDirector, can you help me?
I would like to have:
port you used;
cable type;
protocol used (IEC or DLMS)
and parameters
Thank you;

Profile picture for user Kurumi

Kurumi

6 years ago

In reply to Dear friend, by ELMIR

Hi Elmir,

Hi Elmir,

I have answered to you here:
https://www.gurux.fi/comment/17019

BR,
Mikko

mohamedali

5 years 11 months ago

Hi jpaa07

Hi jpaa07
i wish you can help me with reading meter values Elster A1800 from RS485 interface

vietbq95

4 years 8 months ago

Hi Kurumi! I want to read my

Hi Kurumi! I want to read my Elster A1700 but I don't know how to connect to my meter. I using DIGI portserver to convert and connect to my LAN. Can you spen a little time to show me how to read meter data? Thank you so much

Profile picture for user Kurumi

Kurumi

4 years 8 months ago

In reply to Hi Kurumi! I want to read my by vietbq95

Hi Viet,

Hi Viet,

Please, if you have a new question create a new topic. I'll answer your question after you have created a new topic.

BR,
Miko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin