By David_WSE , 23 November, 2012
Forums
DLMSDirector

Hello, I was trying to use Gurux DLMS/COSEM Director to connect to a meter and try
to read some data but got some difficulties:

1st Experiment:
First experiment was with an optical interface (BLUSKY) and a Landis+Gyr meter.
I added the device with the configurations:
Start Protocol: IEC, Media: Serial

Authentication: None
Wait Time: 20, Client Address: 10
Address Type: SerialNumber
Serial number: , Logical Server: 1
Serial Port: COM9, The configurations for Serial Port, are correct.

I used Gurux Director version 7.0. The log produced by the commands sent to the meter was:

17:38:43 Initializing serial connection.
17:38:43 HDLC sending:/?95387665!
17:38:45 HDLC received: /LGZ5\2ZMG3104407.P03
17:38:45 BaudRate is : 9600
17:38:45 Moving to mode E.
06 32 35 32 0D 0A
17:38:45 Disconnect request
17:38:45 Failed to receive reply from the device in given time.

I would appreciate if you could explain me what is the "Client Address" field and
the "Logical Server" field.
And also what is the possible reason I can't get a response from the smart meter.

2nd Experiment:
With a serial interface over GSM device, with a Landis+Gyr meter.
I was able to connect, but when requested a read operation, some times got an
error, other times no error but the objects list wasn't filled.

Also I would like to know why in version 7.0 isn't available in the Media, the
"terminal" option.

I used Gurux version 1.0, The configurations used was :

Manufacturer: Landis,
Start Protocol: DLMS, Media: Terminal
Authentication: None
Wait Time: 5, Client Address: 10
Address type: Default
Physical Server: 1, Logical Server: 0
Phone Number: 915328046
Serial port: COM1, All RS232 configurations were correct.

I would like to know why I can view the object list filled with the parameter
from the smart meter after the Read Command?
Because when working with MAP110(App from the manufacturer) I can view the objects
list, and read the data with no problems.

Thank you very much for any support or hint.

This is the LOG:

17:57:32 Initializing Terminal connection.
17:58:02 Send SNRM request.
7E A0 07 03 21 93 0F 01 7E
17:58:03 Reveived data
7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 3E 07 04 00 00 00 01 08 04 00 00
00 01 07 22 7E
17:58:03 Parsing UA reply.
7E A0 07 03 21 93 0F 01 7E
17:58:03 Parsing UA reply succeeded.
17:58:03 Send AARQ request
E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 02 BE 10 04 0E 01 00 00 00 06 5F 1F
04 00 1C 03 20 FF FF
17:58:03 Reading object System.Byte[] from interface None
7E A0 2B 03 21 10 FB AF E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 02 BE 10 04
0E 01 00 00 00 06 5F 1F 04 00 1C 03 20 FF FF 80 AB 7E
17:58:05 Reveived data
7E A0 37 21 03 30 6C 7C E6 E7 00 61 28 A1 09 06 07 60 85 74 05 08 01 02 A2 03 02
01 00 A3 05 A1 03 02 01 00 BE 0F 04 0D 08 00 06 5F 1F 04 00 18 02 20 0B B8 FA 00
B1 D8 7E
17:58:05 Parsing AARE reply
7E A0 37 21 03 30 6C 7C E6 E7 00 61 28 A1 09 06 07 60 85 74 05 08 01 02 A2 03 02
01 00 A3 05 A1 03 02 01 00 BE 0F 04 0D 08 00 06 5F 1F 04 00 18 02 20 0B B8 FA 00

B1 D8 7E
17:58:05 Parsing AARE reply succeeded.
Port set failed: Failed to set new values. Media is open.
18:02:27 --- Collecting objects. ---
18:02:27 Collecting objects
7E A0 11 03 21 32 B7 3D E6 E6 00 05 01 02 FA 08 18 9E 7E
18:02:28 Reveived data
7E A0 07 21 03 1F 6B E9 7E
18:02:37 --- Collecting objects. ---
18:02:37 Collecting objects
7E A0 11 03 21 54 87 3B E6 E6 00 05 01 02 FA 08 18 9E 7E
18:02:39 Reveived data
7E A0 07 21 03 1F 6B E9 7E

minhvc

13 years ago

Have you tried start with

Have you tried start with dlms and net media?

Profile picture for user Kurumi

Kurumi

13 years ago

Difficulties with Gurux DLMS/COSEM Director

Hi,

Thanks minhvc and sorry that no one has not answered for you. For some reason we have miss your post. :-(

Try to read with latest version from GXDLMSDirector. If you still have problemns send log file to Forum and we will tell what is the problem.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin