By muraligowda980… , 18 November, 2025
Forums
DLMSDirector

Hi,

I am trying to upgrade firmware to a TCP wrapper meter using GXDLMSDirector.

During the process, Gurux application is retrying image verification stage indefinitely until the disconnection request or power off.

GXDLMSDirector Application Version:- 9.0.2409.2004

I have attached log for your reference.

15:26:33 Updating image RH16.01.00_FIELD...
TX: 7E A0 2E 03 A1 B6 5C 8D E6 E6 00 CB 20 30 00 00 07 5D 20 D5 97 E9 25 7A A9 FB 6A B9 BA 79 CB 5D 27 FA A4 13 FC B6 04 5E DC B4 A0 A9 85 09 3E 7E
15:26:33
RX: 7E A0 24 A1 03 9A BC 9C E6 E7 00 CF 16 30 00 00 04 B9 55 2B 1C A0 7F 1E 92 10 37 A8 02 7B 19 98 0C 7D 23 7F BF 7E

15:27:54 Updating image RH16.01.00_FIELD...
TX: 7E A0 2E 03 A1 B6 5C 8D E6 E6 00 CB 20 30 00 00 07 65 A3 C5 37 E5 19 D5 93 09 BB D8 15 9A AD 8D DA 39 4D A5 3E FF 26 8A 31 40 3D AE 7B 67 6C 7E
15:27:54
RX: 7E A0 24 A1 03 9A BC 9C E6 E7 00 CF 16 30 00 00 04 C1 C1 E4 8C 8A 42 DC CD E9 B6 D2 50 26 E7 6F B5 80 D5 DA 27 7E

Request you to help me to come out of this ASAP as it an emergency.

Regards,
Murali

Profile picture for user Kurumi

Kurumi

10 months ago

Hi Murali, Your data is…

Hi Murali,

Your data is encrypted, so it doesn't help because you didn't give the block cipher key.

The meter might reply temporary failure error, which means the image verification is still in progress, and the client should try again in a while. That is done until the meter returns success.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin