3 Phase meter Frames are as under
08:16:20 Send SNRM request.
TX: 7E A0 07 03 41 93 5A 64 7E
08:16:20
RX: 7E A0 20 41 03 73 3E 9D 81 80 14 05 02 03 40 06 02 03 40 07 04 00 00 00 01 08 04 00 00 00 01 B7 29 7E
08:16:20 Send AARQ request.
TX: 7E A0 57 03 41 10 DF 07 E6 E6 00 60 49 A1 09 06 07 60 85 74 05 08 01 03 A6 0A 04 08 41 42 43 44 45 46 47 48 8A 02 07 80 8B 07 60 85 74 05 08 02 01 AC 0A 80 08 4E 43 43 4D 53 45 4C 4C BE 17 04 15 21 13 20 00 00 00 00 F7 52 BF B3 AB 60 AE E5 78 1E 55 59 EF F5 4D B6 7E
08:16:21
RX: 7E A0 40 41 03 30 45 74 E6 E7 00 61 32 A1 09 06 07 60 85 74 05 08 01 03 A2 03 02 01 01 A3 05 A1 03 02 01 02 A4 0A 04 08 43 52 59 00 00 9C DE BB BE 0D 04 0B 28 09 20 00 00 01 71 F7 C3 61 EB EA 7C 7E
08:16:21
RX: 7E A0 20 41 03 73 3E 9D 81 80 14 05 02 03 40 06 02 03 40 07 04 00 00 00 01 08 04 00 00 00 01 B7 29 7E
We re getting ServiceError Initiate Exception. Initiate Incompatible Conformance
Hi, The data is encrypted. I…
Hi,
The data is encrypted. I need the block cipher key so I can check the bytes.
BR,
Mikko