By MikeAtson1 , 8 May, 2025
Forums
DLMSDirector

Hi,

I already shared a message about that. Still not found solution. And also I tried Landis+Gyr E550 meter.

Starting to execute test for ll.
Starting HDLC tests #1.
Receiver Ready failed.Failed.
<a href="https://www.gurux.fi/gurux.dlms.ctt.tests#hdlc1">Test #1 failed.</a>Starting HDLC tests #2.
Timeout.Failed.
<a href="https://www.gurux.fi/gurux.dlms.ctt.tests#hdlc2">Test #2 failed.</a>Starting HDLC tests #3.
Timeout.Failed.
<a href="https://www.gurux.fi/gurux.dlms.ctt.tests#hdlc3">Test #3 failed.</a>Starting HDLC tests #4.
Timeout.HDLC Illecal frame test (Opening flag missing).
HDLC Illecal frame test (Closing flag missing).
HDLC Test #4. HDLC Illecal frame test (Both flags are missing).
Timeout.Failed.
<a href="https://www.gurux.fi/gurux.dlms.ctt.tests#hdlc4">Test #4 failed.</a>Starting HDLC tests #5.
Timeout.SNRM request failed. Failed to receive reply from the device in given time.Failed.
<a href="https://www.gurux.fi/gurux.dlms.ctt.tests#hdlc5">Test #5 failed.</a>Starting HDLC tests #6.
Timeout.

like that. Those are also failed.

This is last test between Gxdirector and Stm - Dlms Stack
11:51:52 Initializing serial connection.
11:51:53 Send SNRM request.
7E A0 07 03 21 93 0F 01 7E
11:51:53
7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
11:51:53 Parsing UA reply succeeded.
11:51:53 Send AARQ request.
7E A0 2B 03 21 10 FB AF E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 62 1E 5D FF FF 88 55 7E
11:51:53
7E A0 37 21 03 30 6C 7C E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 1E 1D 02 00 00 07 7A ED 7E
11:51:53 Parsing AARE reply succeeded.
11:51:53 Disconnect request
11:51:53 HDLC test #1. Disconnect request
7E A0 07 03 21 53 03 C7 7E
11:51:53
7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
11:51:53 HDLC test #1. SNRM request
7E A0 07 03 21 93 0F 01 7E
11:51:53
7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
11:51:53 HDLC test #1. Receiver Ready
7E A0 07 03 21 11 15 A6 7E
Data send failed. Try to resend 1/3
11:52:18 Data send failed. Try to resend 1/3
7E A0 07 03 21 11 15 A6 7E
11:52:18
7E A0 07 21 03 11 15 00 7E 7E A0 07 21 03 97 2B E1 7E
11:52:18 Disconnect request
11:52:18 HDLC test #1. Disconnect request
7E A0 07 03 21 53 03 C7 7E
11:52:18

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06