By JavierDiaz , 17 August, 2023
Forums
Gurux.DLMS

Hi,
I have xml file and string connect for start simulator:
Gurux.DLMS.Simulator.Net.exe -p 1000 -x sim.xml -t Verbose -N 1 -a None -c 7 -s 1 -l 0.

Simulator meter settings:
Start protocol - DLMS
Authentification - None
ClientAddress - 7
Logical Server - 0
Physical server - 1
Host - localhost
Port - 1000

Log:
DLMS HDLC Logical Name simulator start in ports 1000-1000.
Waiting 1.00:00:00 before next execution.
Server address: 1
Associations:
++++++++++++++++++++++++++++
Client address: 1 HighECDSA authentication, password
Conformance:
ReservedZero, GeneralProtection, GeneralBlockTransfer, Read, Write, ReservedSeven, BlockTransferWithGetOrRead, BlockTransferWithSetOrWrite, SelectiveAccess
MaxReceivePduSize: 1000 MaxSendPduSize: 1000

Security suite: Suite0
Security policy: None
Authentication key: D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF
Block cipher key: 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
Broadcast block cipher key: 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F

++++++++++++++++++++++++++++
Client address: 0 Without authentication.
Conformance:
None
MaxReceivePduSize: 0 MaxSendPduSize: 0

++++++++++++++++++++++++++++
Client address: 0 Without authentication.
Conformance:
None
MaxReceivePduSize: 0 MaxSendPduSize: 0

When trying to connect to a virtual device, an error occurs:
"ServiceError Initiate error exception. Initiate IncompatibleConformance".

Please tell me what is my mistake.

Profile picture for user Kurumi

Kurumi

3 years ago

Hi, I believe that your…

Hi,

I believe that your client address is wrong. For some reason, you have two associations where the client address is zero and that is not correct.

BR,
Mikko

JavierDiaz

2 years 10 months ago

Thanks, it works!

Thanks, it works!

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin