By 953313493@qq.com , 9 May, 2023
Forums
DLMSDirector

hello,
about gateway I have some problem.

how to set the gateway clientID and meter id when both of them use hdlc

if client use rs485 to gateway and gateway use rs485 to meter
client --HDLC-- gateway--HDLC--meter

1. client should send snrm to gateway,
2. gateway respone ua
3. client send gateWay protocol E6 xx AARQ
4, the gateway send snrm to meter or hdlc with aarq?

otherwise , gateway---meter clientId should be what?

Profile picture for user Kurumi

Kurumi

3 years ago

Hi, HDLC is used to send…

Hi,

HDLC is used to send frames and it has own server and client address. You can give network ID and physical device address for the gateway.

Usually gateways are transparent and they just forware received data.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin