when I read the L1 Voltage in the GXDLMS Director, I wonder 2 times the read command packet was observed in Log File.

Please mention the Comments below mention read command and Response from the Device.

Note: In the Director, I was sent 1 time to Read the L1 Voltage.

L1 voltage read:-
17:37:25 Read object type Register index: 3
TX: 7E A0 19 03 41 32 3A BD E6 E6 00 C0 01 C1 00 03 01 00 20 07 00 FF 03 00 5D 9A 7E
17:37:25
RX: 7E A0 16 41 03 52 DD AA E6 E7 00 C4 01 C1 00 02 02 0F 00 16 23 07 3E 7E
17:37:25 Read object type Register index: 2
TX: 7E A0 19 03 41 54 0A BB E6 E6 00 C0 01 C1 00 03 01 00 20 07 00 FF 02 00 85 83 7E
17:37:25
RX: 7E A0 15 41 03 74 24 CB E6 E7 00 C4 01 C1 00 17 46 A1 7A 00 EB A2 7E

Profile picture for user Kurumi

Kurumi

3 years 3 months ago

Hi, You are reading two…

Hi,

You are reading two objects from the meter. At first the scaler and unit first and then the actual value.

BR,

Mikko

suri371994

3 years 3 months ago

As per your reply consider…

As per your reply consider 1st Request packet is Scaler Unit:-

7E //Start Frame
A0 //Des.Address
19 //Length
03 //server address
41 //client address
32 //Instance Value
3A BD //header CRC
E6 // Des. LSAP
E6 //Source LSAP
00 // LLC Quality Reserved for Future.
C0 01 C1
00 03 //OBIS Class Id
01 00 20 07 00 FF //( OBIS Code -- 1.0.32.07.0.255 )
03 //Attribute Id
00 //Instance
5D 9A //CRC ( FCS-16 )
7E //End Frame

2nd Request packet is the Actual value:-

7E //Start Frame
A0 //Des.Address
19 //Length
03 //server address
41 //client address
54 //Instance Value
0A BB //header CRC
E6 // Des. LSAP
E6 //Source LSAP
00 // LLC Quality Reserved for Future.
C0 01 C1
00 03 //OBIS Class Id
01 00 20 07 00 FF //( OBIS Code -- 1.0.32.07.0.255 )
02 //Attribute Id
00 //Instance
85 83 //CRC ( FCS-16 )
7E //End Frame

If I try to read straightaway actual value, I will get any error?

Note: I think Attribute Id will play key importance in the parameter reading, is it? (Scaler unit=3,Actual value=2)

Please mention the Instance of each data packet's importance.

suri371994

3 years 3 months ago

### Receive packet…

### Receive packet Description.
//Scaler unit response.
7E //Start Frame
A0 //Des.Address
16 41 03 52 DD AA
E6 // Des. LSAP
E7 //Source LSAP Response
00 // LLC Quality Reserved for Future.
C4 01 C1 //
00 02 02 0F 00 16 23
07 3E //CRC ( FCS-16 )
7E //End Frame

//Actual value response.
7E //Start Frame
A0 //Des.Address
15 41 03 74 24 CB
E6 // Des. LSAP
E7 //Source LSAP Response
00 // LLC Quality Reserved for Future.
C4 01 C1 //
00 17
46 A1 7A 00 //Value received ( 20669.000V )
EB A2 ////CRC ( FCS-16 )
7E //End Frame

Also, describe unknow data packet details.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin