Hi,

I'm exploring GURUX and all things involved in this community. But I'm also still learning DLMS/COSEM, more specifically the server model, and I have a doubt about the AA between a server and a client. So I'm doing this topic to request help =).

Whats the expected behavior of a class 15 object when a the same client, like public client, access a same logical device, like the manager, using 2 different communications ports of a physical device? (In each port, different contexts can be accordded)

Have I a way to differentiate the connections between a same client and server but in different physical networks at same time?

A answer to this question I'll help me a lot to understand how DLMS/COSEM works.

Bests Regards,
Gabriel Lira

Profile picture for user Kurumi

Kurumi

3 years 8 months ago

Hi Gabriel, It's basically…

Hi Gabriel,

It's basically possible to establish multiple simultaneous connections, but usually, the meters allow only one connection at a time. The main reason for this is a lack of memory and CPU.

You need to create your own server for each communication port to make this possible.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • Need RJ45 pin configuration for Saral 300 and Saral 305 Secure meters
  • Query Regarding Class 63 Status Mapping Support in Gurux DLMS Python
  • Inhemeter
  • DLMS Server - Profile Generic - can't add too many items to profile generic capture object - how to set maximum profile entries
  • HDLC Frames sequencing
More

Who's new

  • Asier Sierra
  • BlessyAnn
  • sravya.thota@m…
  • Diwakar
  • williamorussell
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin