Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Forums
  3. Class 15 Object Return When Client Connecting With One Logical Device Through Many Communication Ports

Class 15 object return when client connecting with one logical device through many communication ports

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Gabriel Lira , 17 February, 2023
Forums
General discussion

Hi,

I'm exploring GURUX and all things involved in this community. But I'm also still learning DLMS/COSEM, more specifically the server model, and I have a doubt about the AA between a server and a client. So I'm doing this topic to request help =).

Whats the expected behavior of a class 15 object when a the same client, like public client, access a same logical device, like the manager, using 2 different communications ports of a physical device? (In each port, different contexts can be accordded)

Have I a way to differentiate the connections between a same client and server but in different physical networks at same time?

A answer to this question I'll help me a lot to understand how DLMS/COSEM works.

Bests Regards,
Gabriel Lira

Profile picture for user Kurumi

Kurumi

3 years 5 months ago

Hi Gabriel, It's basically…

Hi Gabriel,

It's basically possible to establish multiple simultaneous connections, but usually, the meters allow only one connection at a time. The main reason for this is a lack of memory and CPU.

You need to create your own server for each communication port to make this possible.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • gurux_dlms.GXDateTime.GXDateTime object Error in Python
  • T_APPL_DATA_LN_N1 subtest 3 fails on an LN-only server regardless of the response to a non-existing-object GET
  • Version mismatch between Gurux.DLMS 9.x and Gurux.Common/Gurux.Serial 8.x
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
More

Who's new

  • qZgCuGshgQLxtN…
  • Georgegeowl
  • brsRKNujhfnXWm…
  • TmncVuWXpMBjtlVn
  • suMPQCGuZJqlCP…
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin