Hi
I'm using Gxdlmsdirector for set/get my electric meter, first of all thanks for your free software , its great.
now i want use Pre-Established client to set clock in GxdlmDirector
but i cant set parameters in Gxdlmsdirector , i can use Public/Reading and Management , But i cant use Pre-Established client , how should i do the settings?

thank you.

Profile picture for user Kurumi

Kurumi

3 years 9 months ago

Hi,

Hi,

Select the "Secured connections" tab from the meter settings. Then set the pre-established system title. Pre-established system title is the system title of the meter.

BR,
Mikko

dlmsDeveloper

3 years 9 months ago

thank you.

thank you.
thats work , awsome.

another question

in Pre-Established client for unicast message , Should the meter answer or not?

thank you.

Profile picture for user Kurumi

Kurumi

3 years 9 months ago

Hi,

Hi,

There is usually an own association view for pre-established connections. Client address defines what association view is accessed.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • Anaglyfos Trading CC
  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin