By kuba245 , 13 January, 2022
Forums
DLMSDirector

Hi,
I'm trying to read Polish Apator meter via Gurux Director with no success. The meter is available via public ip address. Maybe anyone connecting via Gurux to this meter? Data to connect which provider send to me are:
Manufacturer identifier : APAESX30
Authentication: High
Password: 01234567

Serial number and address ip with port.

Profile picture for user Kurumi

Kurumi

4 years 4 months ago

Hi,

Hi,

Can you read this with the manufacturer's software? If you can, record the messages with wireshark and send output to me by email. I can check the correct values for you.

BR,
Mikko

kuba245

4 years 4 months ago

In reply to Hi, by Kurumi

Unfortunately I don't have

Unfortunately I don't have manufacturer software, because it's licensed. I have contact to them so maybe I will try to get correct frame from them.

Profile picture for user Kurumi

Kurumi

4 years 4 months ago

Hi,

Hi,

There are so many different parameters and searching them might take a long time.
It's faster if you can get the correct parameters from the manufacturer.

BR,
Mikko

kuba245

4 years 4 months ago

I get this data from

I got this data from manufacturer:

IP WRAPPER, association public:

000100100001001f601da109060760857405080101be10040e01000000065f1f040000fc1fffff

Profile picture for user Kurumi

Kurumi

4 years 4 months ago

Hi,

Hi,

Change interface from HDLC to WRAPPER. Then set the IP address and port and establish the connection.
Let me know if you succeeded to connect and default settings are added for the manufacturer so it's easier to connect in the future.

BR,
Mikko

kuba245

4 years 4 months ago

Yes now working with this

Yes now working with this setting. But I cannot sea Load profiles on list. but there is a partial success.

Image
Profile picture for user Kurumi

Kurumi

4 years 4 months ago

Hi,

Hi,

I believe that you need to connect using an authenticated connection.
You need the password and then you need to change the client address.
You should ask for this information from the manufacturer.

BR,
Mikko

kuba245

4 years 4 months ago

Hi,

Hi,
I used authentication in High level with password from manufacturer. And I'm trying to connect using client address 10 and I get an error: connection is permanently rejected. Authentication error.

I ask manufacturer for proper client address but they said that communication should look like:
We are connecting with meter using public connection without password, after connection program should send password and authentication method and after that secured connection is set between program and meter.

Profile picture for user Kurumi

Kurumi

4 years 4 months ago

Hi,

Hi,

That sounds strange. For all other meters, there is own client address for each authentication.
The client should also tell what authentication it's using when the connection is made.
After connection client sends a challenge for the meter and not the password, but maybe this is a misunderstanding.

Can you add a hex trace when you establish the connection from the meter? You can get it when you select "Edit" "Log" and "View Log..".

Those two lines are enough. Don't add reading association view, etc. I'll check what meter is returning on connection.

BR,
Mikko

kuba245

4 years 4 months ago

In reply to Hi, by Kurumi

This will be enough? This is

This will be enough? This is connection in public without authentication. Additionally they said that security policy in them meter are authenticated and encrypted.

13:50:53 Send AARQ request.
00 01 00 10 00 01 00 1F 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 20 1E 5D FF FF
13:50:54
00 01 00 01 00 10 00 2B 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 12 14 01 80 00 07
13:50:54 Parsing AARE reply succeeded.

Profile picture for user Kurumi

Kurumi

4 years 4 months ago

Hi,

Hi,

Authentication means that you can do different things for the meter. Example update the clock.
Security policy means that messages are ciphered (encrypted and/or authenticated).

Meters returns normal reply when connecting without authentication.

Do you have authentication and block cipher keys? They are 16 bytes long values that are needed if ciphering is used. Each manufacturer has different keys. You need those if you want to connect with ciphering or using GMAC authentication.

BR,
Mikko

kuba245

4 years 4 months ago

In reply to Hi, by Kurumi

No I don't have a

No I don't have a authentication and block cipher keys. So I ask the manufacturer for that. Do you think that could be necessary for read load profiles? Now I get from them this:
<keys>
<key name="authentication" hexvalue="E614893AA64847A49559372A0BACC667" />
<key name="broadcast" hexvalue="30303030303030303030303030303031" />
<key name="unicast" hexvalue="274A85B933CC30361483972763CD81AB" />
</keys>
<password type="HLS_GMAC" hexvalue="706A5A586557794F" />

They said that they changed the password for 01234567 but they not sure that password is really change to that password.

Profile picture for user Kurumi

Kurumi

4 years 4 months ago

Hi,

Hi,

Select "Secured connections" tab from meter settings and
Set authentication key to "Authentication key" and Unicast to "Block cipher key".
Then change Security from None to "AuthenticationAncryption".

Change Authentication from None to HighGMAC.

GMAC doesn't use passwords, so forget password hexvalue and try to connect.
If it fails, try to set 706A5A586557794F to "Secured connections" Challenge field.

I hope that you can connect.

BR,
Mikko

kuba245

4 years 4 months ago

I have one more question:

I have one more question: what set into a filed: system title?

Profile picture for user Kurumi

Kurumi

4 years 4 months ago

Hi,

Hi,

The client system title can usually be any 8 bytes long value. I notest that in your settings password
length is 8. To this:
pjZXeWyO

It's 706A5A586557794F in ASCII format.

BR,
Mikko

kuba245

4 years 4 months ago

In reply to Hi, by Kurumi

I set all the paremeters that

I set all the paremeters that you suggested but I still cannot connect with the meter. When I try to connect with GMAC and client adress 10 I get error: Connection is permanently rejected The application context name is not supported. Meter Expects Logical Name Referencing.
I have set option for logical name referencing.
There is a response for client address 10 and authentication GMAC:
10:35:26 Send AARQ request.
00 01 00 10 00 01 00 57 60 55 A1 09 06 07 60 85 74 05 08 01 03 A6 0A 04 08 70 6A 5A 58 65 57 79 4F 8A 02 07 80 8B 07 60 85 74 05 08 02 05 AC 0A 80 08 70 6A 5A 58 65 57 79 4F BE 23 04 21 21 1F 30 00 00 00 00 26 74 8B 20 D2 6F D5 EE AE 99 73 D8 C1 B1 FB 29 1E 44 ED 7F 47 B0 C0 E1 A3 AF
10:35:26
00 01 00 01 00 10 00 2B 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 01 A3 05 A1 03 02 01 02 BE 10 04 0E 08 00 06 5F 1F 04 00 00 12 14 01 80 00 07

When I change client address for 14 the meter doesn't response. I attached the setting for secured connection.

Image
Profile picture for user Kurumi

Kurumi

4 years 4 months ago

Hi,

Hi,

You need to change your client address to something else than 0x10. You can try with 1 and 0x11.
Ask what client address should be used from the meter manufacturer if fails.

BR,
Mikko

kuba245

4 years 4 months ago

Finally I connected with this

Finally I connected with this meter. I was changing client address as you mentioned and I finally hit it in address 0x02. Now I have got full access to the meter and can read Load profiles. Thank you for your help.

Profile picture for user Kurumi

Kurumi

4 years 4 months ago

Hi,

Hi,

Thank you for this information. Sometimes it's pain to find the correct settings because only the manufacturer knows them. Now it should be easy.

BR,
Mikko

mch35

4 years 1 month ago

In reply to No I don't have a by kuba245

Hi, kuba245, can you write

Hi, kuba245, can you write the email address which you used to ask for these authentication details?

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin